INSTRUCTIONS MANUAL
-99-
1
FIG. 33
v
EMPTYING THE USED OIL CONTAINER
Procedure:
1. Press quick connection button (ref 1, Fig.33) to disconnect the used olio container
2. Lift the used oil container out of its lodging (ref v, Fig.33) without exerting pressure on
the scale.
3. Unscrew the cap (ref 2, Fig.34) while holding the container; empty the used oil into a
suitable container for used oils (Fig.35).
4. Screw the cap back into the container.
5. Replace the container and hook it up to the quick connection taking care not to exert
pressure on the scale in order not to damage it.
NOTE:
In order to avoid damage to the oil scale, never exert pressure on it either from above
or from below.
FIG. 34
2
FIG. 35