Press OK to confirm the displayed values and start the procedure, BACK to return back.
The following screen will be displayed:
Connect and open the coupling to the A/C system, then press OK, press BACK to return back.
the AUTOMATIC PROCEDURE will start, and the following screen will be displayed:
During the recovery phase, the machine displays the quantity of refrigerant recovered, in
grams. Upon completion of recovery, the machine will stop and discharge, while automatically
displaying the used oil extracted from the A/C system during the recovery phase.
The oil discharge operation lasts 4 minutes.
The machine checks whether or not there is air in the bottle and, if necessary, purges the non-
condensable gas; The machine will automatically discharge any non-condensable gas.
Allowing the machine to fully complete the procedure will reduce the risk of return flows, which
may cause excessive non-condensable gas to be recharged into the air conditioning system. If
any residual refrigerant in the A/C system should increase in pressure during this phase, the
machine will automatically begin recovering the refrigerant.
Completed the recovery phase, the machine automatically goes on to running the vacuum
phase for the preset time:
GAS EXTRACTION FROM A/C SYSTEM 1
st
PHASE
Recovered gas
Bottle Pressure
A/C pressure
Bottle temperature
R134a AUTOMATIC PROCEDURE
RECOVERY / RECYCLE
Connect and open HP and LP coupling to A/C
system press OK
R134a AUTOMATIC PROCEDURE
RECOVERY / RECYCLING
USED OIL DISCHARGE
Recovered gas
Bottle Pressure
Recovered oil
R134a AUTOMATIC PROCEDURE
RECOVERY / RECYCLE
R134a AUTOMATIC PROCEDURE
VACUUM TIME
OIL INJECTION
UV
GAS FILLING
CONNECTION MODE
VEHICLE PLATE
Press OK to start the procedure