![Ecostrad Ecowarme Instruction Manual Download Page 7](http://html1.mh-extra.com/html/ecostrad/ecowarme/ecowarme_instruction-manual_2355472007.webp)
Ecostrad_Ecowärme_V1.2_09022022
7
3 | Technical Information
4 | Installation
The Ecostrad Ecowärme Electric Radiator should be mounted on a
load-bearing wall using the fixings provided. Always observe the minimum
safety clearances stated in
.
4-1 | Wall mounting instructions
1. Read all safety instructions and warnings stated in the preceding section
of this manual. Failing to follow these instructions can cause damage to
life or property.
2. Remove all packaging, making sure no packaging residue remains on the
radiator.
3. Drill four holes in the wall as per
provided with radiator.
Table 1 | Specifications
Heating element
X-bar element and ceramic core
Voltage
230V AC / 50 Hz
Wattage
500W, 1000W, 1200W, 1500W,
2000W
Temperature setting
Range
Resolution
5-30 °C
0.5 °C
IP Rating
IP20
Appliance class
Class I
Power cable length
1.5m
Table 2 | Minimum safety distances
Between the sides of the radiator and any
masonry
5cm
Between the sides of the radiator and
flammable materials
10cm
From the radiator to the floor
8cm
From the top of the radiator to any covering
above
If flammable (i.e wooden window sill)
If non-flammable (i.e brick alcove)
15cm
10cm