 6 | Cleaning & Maintenance

The Ecostrad Ecowärme Electric Radiator uses an unenclosed aluminium convection 

element to deliver fast heat distribution. This can reach higher internal temperatures 

when compared to other radiator products. However, the outer surface temperature 

is not affected by this and the element cannot be touched. The higher internal heat 

level can however cause dust particles in the air to burn when they pass through the 

unit. We therefore recommend in particularly dusty environments cleaning the 

radiator on a regular basis and where possible minimising the production of dust or 

smoke to help prevent potential wall blackening.
When cleaning, always:
• Ensure the radiator is disconnected from the power before attempting 

any cleaning or maintenance. Failure to do so may incur risk of electric 

shock.

• Clean the radiator with a dampened cloth. Do not use abrasive materials or 

chemicals which may damage the radiator. 

• Allow the radiator to fully dry before reconnecting to the power. 

 7 | Warranty 

The Ecostrad Ecowärme Electric Radiator carries a 5-year guarantee on the body, a 

3-year guarantee on the paintwork, and a 2-year guarantee on electrical 

components. Within the stated period, starting from the date the customer receives 

their unit, Ecostrad guarantee to repair or replace the unit where a fault is due to 

defects in materials or manufacturing. 
The warranty does not cover any defect arising from damage, negligence, usage 

outside the product’s intended purpose or fair wear and tear. The warranty is only 

valid when the unit has been used at the specified supply voltage, and in accordance 

with all conditions specified in this manual. The warranty will be void if the heater has 

been covered, tampered with or opened in any way, or if the ratings label has been 

removed. 
The warranty does not cover failures and faults due to force majeure, accidental 

damage, mishandling, external impact, chemical agents or atmospheric phenomena, 

incorrect use of the device, the purchaser’s faulty electrical installations, transporting 

the device or problems caused by the device being handled by persons not 

authorised by Ecostrad. If the unit has been hardwired, an invoice may be required 

to confirm the work was carried out by a qualified professional. Ecostrad cannot 

accept responsibility for damage, loss or injury caused by incorrect installation, 

maintenance, cleaning or covering the device.
The warranty is a contract with the original purchaser and does not transfer if the unit 

is re-sold, gifted or inherited. Proof of purchase, including order number and order 

confirmation or invoice, will be required if a claim is made. 
The warranty covers only the model of heater shown on the purchase invoice. The 

warranty covers the repair or replacement of the defective product only and Ecostrad 

shall have no liability for installation costs or consequential losses however incurred. 

The unit is sold as a DIY product; whilst hardwiring is permitted within the terms of the 

Summary of Contents for Ecowarme

Page 1: ...Ecostrad Ecow rme Electric Radiator PLEASE READ AND SAVE THESE INSTRUCTIONS...

Page 2: ...immediately after operation Hot surfaces should not be touched danger of burns Observe instructions in manual This symbol located on the device indicates that instructions in the operating manual must...

Page 3: ...nformation 7 4 Installation 7 4 1 Wall mounting instructions 7 4 2 Feet fixing instructions 8 5 Control Panel 10 5 1 Display 10 5 2 Setting the time 11 5 3 Standby mode 11 5 4 Heating modes 11 5 5 Adv...

Page 4: ...or all of the above Save all warnings and instructions for future reference Warning This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or men...

Page 5: ...d by the manufacturer its service agent or similarly qualified persons to avoid a hazard All repairs and servicing must be carried out by a qualified person To avoid danger any repairs must be complet...

Page 6: ...als like dust gas or vapour cannot be avoided Do not use in rooms or environments that have a corrosive atmosphere Avoid humid surroundings Do not operate the device when wet If the device gets wet du...

Page 7: ...idue remains on the radiator 3 Drill four holes in the wall as per Table 3 Figure 1 and the drilling template provided with radiator Table 1 Specifications Heating element X bar element and ceramic co...

Page 8: ...duced after 2019 are compatible with the feet You can check if your radiator is compatible by confirming the presence of 3 holes used for fixing the feet on each side of the back of the heater see Fig...

Page 9: ...2022 9 1 Slot the feet into the ribs and line up the holes as in Figure 3 2 Fix in place with 6 screws as in Figure 4 Figure 2 Feet fixing holes on compatible models Figure 3 Fixing the feet Figure 4...

Page 10: ...andby and changing mode and each of the upper four buttons corresponds to the icon directly above it on the control screen See Figure 6 Temperature if it is room temp will show Day of the week Auto or...

Page 11: ...flash again You can repeat the above process to change anything if you made a mistake When you are happy press the Standby Button to exit the menu 5 3 Standby mode In standby mode the current room te...

Page 12: ...omfort set temperature So when you first turn on your radiator you will not see and in Eco mode The Eco set temperature will change according to the set temperature you choose for Comfort mode You can...

Page 13: ...numbers 1 7 with an arrow pointing to 1 this indicates that you are setting the mode for Monday at midnight 1 Choose the desired mode for this hour by clicking on the button beneath the corresponding...

Page 14: ...ce mode ends the radiator will return to Auto mode meaning your home will be perfectly warm for when you return To enter Absence mode 1 Press MODE until the radiator is in Auto mode 2 Then press the b...

Page 15: ...st for any discrepancy between the average room temperature and the temperature sensed by the thermostat For instance if the temperature in the room is 18 C but the radiator is sensing and displaying...

Page 16: ...6 Adaptive start The sixth option indicated by the arrow pointing to 6 is for the adaptive start setting Adaptive start is a feature which will pre emptively turn on the radiator to start heating the...

Page 17: ...e warranty does not cover any defect arising from damage negligence usage outside the product s intended purpose or fair wear and tear The warranty is only valid when the unit has been used at the spe...

Page 18: ...nimum heat output indicative Pmin kW 0 5 1 0 1 2 1 5 2 0 Maximum continuous heat output Pmax c kW 0 5 1 0 1 2 1 5 2 0 Auxiliary electricity consumption At nominal heat output elmax kW 0 5 1 0 1 2 1 5...

Page 19: ...uman health caused by the disposal of hazardous substances potentially contained in the equipment Type of heat output room temperature control select one single stage heat output and no room temperatu...

Reviews: