TECHNICAL FEATURES C7944

 

General characteristics

Electric grey scissor-shaped technical table.

Standard upholstery dimensions: 62x207 cm (M48)

Recommended maximum weight: 200 Kg

Height variation: 48-97 cm
Electric motor-controlled height adjustable by side rails system.
Height adjustment without side misalignment

Steel frame with grey epoxy powder coating heated at 250°C
90 mm diameter steel legs. With 4 table levellers, one in each leg.
Retractable castors with foot lever.  Just for moving the table around, NOT intended for patient transportation.
Detachable chrome paper roll holder included as standard.

Standard headrest type T03 - Headrest with adjustable arm supports. Rectangular breather hole and bung included.
Set of folding armrests (non-removable)

Head-/Backrest adjustable by gas spring.

Approx. weight: 85 Kg

Upholstery Features
Fire-resistant Class M2 artificial leather, EC compliant.
Sanitized® anti-microbial and antibacterial protection.
Available in 22 colours.
Foam thickness 4 cm.
Foam firmness III - Medium firm

 

Electric Motor Features
Stroke length: 300 mm
Asynchronous motor 1-230V. AC ±10%
Integrated thermal protection
Max. Power: 8000N - Average speed at load 0: 14mm/s
Voltage: 230V/50-60 Hz - Power consumption: 3,7A
Working cycle: 25s non stop / 400s off
Safety class: I - Standard protection: IP44
EMI (electromagnetic interference) Directive compliant

Summary of Contents for C7944

Page 1: ...ILLA EL CTRICA ELECTRIC TABLE TABLE LECTRIQUE INSTRUCCIONES INSTRUCTIONS Leer antes de utilizar por primera vez Read carefully before the first use A lire avant la premi re utilisation Actualizaci n 0...

Page 2: ...zas defectuosas o usadas deben reponerse inmediatamente utiliz ndose nica y exclusivamente las piezas originales de repuesto del fabricante para cada modelo en concreto Todo accesorio parte o pieza de...

Page 3: ...paciente pueda subir bajar por el lateral c modamente Atenci n Evitar que se impulse en el apoyabrazos para levantarse pues podr a romperse c Regulaci n de la ALTURA El sistema de elevaci n es mediant...

Page 4: ...u s de pasar unas horas proceder de manera inversa y hacer lo mismo por el otro lado de la camilla Evitar la colocaci n permanente de la camilla en zonas con un alto grado de humedad b MOTOR el ctrico...

Page 5: ...n la garant a los gastos de reparaci n o sustituci n correr n a cargo de Ecopostural incluidos los gastos de reposici n del producto dentro de la U E Para cualquier asunto relacionado con la garant a...

Page 6: ...Espa ol 6...

Page 7: ...Portarrollos abatible cromado incorporado de serie Cabezal standard tipo T03 Cabezal con brazos regulables Orificio rectangular y tap n incluido Brazos abatibles fijos M dulo del cabezal respaldo reg...

Page 8: ...eplaced by original pieces by the manufacturer depending on the table model All components parts or accessories should be fitted or fixed in according to the special manufacturer s instructions Any sp...

Page 9: ...e patient to get up down the side of the table smoothly Caution The patient must not stand up by leaning on the armrest as it could split c HEIGHT adjustment The central height of the table is operate...

Page 10: ...s are tight Please note that the repeated exposure of the table to high levels of humidity is not recommended b Electric MOTOR Keep this piece free from any dust or grease Absolutely avoid spilling li...

Page 11: ...ent In those cases where the guarantee applies Ecopostural will repair or replace the faulty part free of charge and return it at our expense within the EU territory For full details of the guarantee...

Page 12: ...English 12...

Page 13: ...ome paper roll holder included as standard Standard headrest type T03 Headrest with adjustable arm supports Rectangular breather hole and bung included Set of folding armrests non removable Head Backr...

Page 14: ...ent l tat du c ble et de la prise en prenant toutes les pr cautions n c ssaires et en vitant de plier le c ble Les pi ces d fectueuses ou us es doivent tre remplac es imm diatement par des pi ces de r...

Page 15: ...osition assise et pouvoir descendre de la table Attention Le patient ne doit jamais s appuyer sur la t ti re ou le dossier pour s aider se relever car ceux ci ne sont pas con us pour supporter une tel...

Page 16: ...ever la poussi re r guli rement avec un chiffon Les parties mobiles doivent tre graiss es r guli rement avec une graisse en spray qui sera vaporis e sur les points d articulation Mettre la table sur u...

Page 17: ...le cas du simili cuir ne rentre pas dans la garantie Sont galement exclus de la garantie les d fauts et d t riorations provoqu s par un mauvais usage du produit ex nettoyage incorrect de la sellerie m...

Page 18: ...Fran ais 18...

Page 19: ...battable inclus de s rie T ti re standard type T03 T ti re avec appui bras r glables Cavit visage rectangulaire et bouchon inclus Jeu d accoudoirs rabattables fixes T ti re dossier r glable par v rin...

Reviews: