5
Silent mode
Heating
capacity
(
kW)
2.2
2.4
2.5
COP
6.95
6.88
6.92
Ambient Temperature: (DB/WB) 35°C/-; Water Inlet/Outlet Temperature: 30°C/28°
Cooling capacity
(
kW)
1.5~3.1
1.7~3.8
1.8~4.9
Power input
(
kW)
0.208~0.704
0.229~0.854
0.242~1.101
EER
7.2~4.4
7.42~4.45
7.44~4.45
Boost Mode
Cooling Capacity
(kW)
3.1
3.8
4.9
EER
4.4
4.45
4.45
Smart Mode
Cooling Capacity
(kW)
2.3
2.92
3.5
EER
5.64
5.63
5.63
Silent Mode
Cooling Capacity
(kW)
1.8
2.18
2.4
EER
6.97
6.97
6.95
Power supply
220-240V/50Hz
Max power input (KW)
1.31
1.61
1.75
Max current(A)
5.95
7.32
7.95
Heating temperature range
15°C
~
40°C
Running temperature range
-10°C
~
43°C
Advised swimming pool size
10m³
~
20m³
15m³
~
30m³
20m³
~
40m³
Refrigerant
R32
Compressor
MITSUBISHI ELECTRIC (DC inverter)
Air side heat exchanger
Hydrophilic fin exchanger
Water side heat exchanger
Titanium tube heat exchanger