5. Electrical Connection
Model
Power Supply Wires
Electricity Supply
Cable Diameter
Specification
NE-F50SP/R4INV-PA
220-240V/50Hz
3×2.5mm
AWG 14
NE-F70SP/R4INV-PA
3×2.5mm
AWG 14
NE-F90SP/R4INV-PA
3×2.5mm
AWG 14
NE-F110SP/R4INV-PA
3×2.5mm
AWG 14
NE-F150SP/R4INV-PA
3×2.5mm
AWG 14
NE-F180SP/R4INV-PA
3×4.0mm
AWG 12
NE-F210SP/R4TINV-PA
380-415V/3Ph/50Hz
3×4.0mm
AWG 12
NE-F250SP/R4TINV-PA
3×4.0mm
AWG 12
NE-F280SP/R4TINV-PA
3×4.0mm
AWG 12
⚠
WARNING: Power supply of heat pump must be disconnected before any operation.
Please comply with the following instruction to connect heat pump.
Step 1: Detach electrical side panel by a screwdriver to access electrical terminal block.
Step 2: Insert cable into heat pump unit port.
Step 3: Connect power supply cable to terminal block according to the diagram below.