9
Model
NE-F210SP/R4TINV-PA
NE-F250SP/R4TINV-PA
NE-F280SP/R4TINV-PA
Ambient Temperature: (DB/WB) 27°C/24.3°C; Water Inlet/Outlet Temperature: 26°C/28°C.
Heating capacity
(
kW
)
4.70~21.1
4.78~25.3
4.95~28.1
Power input
(
kW
)
0.33~3.59
0.33~4.36
0.35~5.1
COP
14.2~5.88
14.48~5.8
14~5.51
Boost
mode
Heating capacity
(
kW
)
21.1
25.3
28.1
COP
5.88
5.8
6.15
Smart
mode
Heating capacity
(
kW
)
17.1
20.36
22.61
COP
7.85
7.38
7.42
Silent
mode
Heating capacity
(
kW
)
10.3
12.53
13.91
COP
10.1
10.8
11.8
Ambient Temperature: (DB/WB) 15°C/12°C; Water Inlet Temperature: 26°C.
Heating capacity
(
kW
)
3.52~14.07
3.61~16.7
4.05~18.5
Power input
(
kW
)
0.460~2.865
0.476~3.394
0.537~3.737
COP
7.65~4.91
7.58~4.92
7.54~4.95
Boost
mode
Heating capacity
(
kW
)
14.07
16.7
18.5
COP
4.91
4.92
4.95
Smart
mode
Heating capacity
(
kW
)
11.13
13.21
14.63
COP
5.69
5.67
5.72
Silent
mode
Heating capacity
(
kW
)
7.09
8.41
9.31
COP
6.65
6.57
6.51
Ambient Temperature: (DB/WB) 35°C/-; Water Inlet/Outlet Temperature: 30°C/28°
Cooling capacity
(
kW)
4.32~10.36
4.52~12.29
4.61~13.61
Power input
(
kW
)
0.586~2.381
0.609~2.799
0.623~3.157
EER
7.37~4.35
7.42~4.39
7.39~4.31
Boost Mode
Cooling Capacity
(kW)
10.36
12.29
13.61
EER
4.35
4.39
4.31
Smart Mode
Cooling Capacity
(kW)
8.04
9.53
10.55
EER
5.26
5.28
5.36
Silent Mode
Cooling Capacity
(kW)
5.56
5.88
6.55
EER
6.55
6.45
6.41
Power supply
380-415V/3Ph/50Hz
Max power input(KW)
4.1
4.8
5.4
Max current(A)
7.3
8.6
10.2
Heating temperature range
15°C
~
40°C
Running temperature range
-10°C
~
43°C
Advised swimming pool size
45m³~80m³
55m³~90m³
65m³~100m³
Refrigerant
R32
Summary of Contents for NE-F50SP/R4INV-PA