Page 26
ecom-
J2KN
pro
TECH
11.3. Pressure measurement (option)
A trend indication for the draught conditions in the exhaust channel
can already be determined during the gas analysis. Nevertheless the
value for the chimney draught will not be stored together with the gas
values while pressing the key
<Memory>
.
Indeed the difference pressure sensor tends to drifts because of its
sensibility and, for an exact measurement it is consequently advised
to re-calibrate the sensor immediately before sampling and
documenting the value.
Access the menu while selecting the
sub-menu
"Pressure"
. The current
value is displayed as well as the
instruction to adjust the zero point of the
sensor. Release hereto the draught
hose from the instrument for a short
moment and press
<F4>
. The sensor is
herewith re-calibrated.
Fix the draught hose again. The display
shows the exact measurement value
which can be stored while pressing
<Memory>
and added to the previous
results in the intermediate memory. The
stored value is shown on the display.
Press
<ESC>
to quit the differential
pressure measurement menu.
For this option a probe
type SB is required!
Pressure
-0.12
hPa
--.-- hPa
New 0 point
Pressure
-0.12
hPa
-0.12 hPa
New 0 point
Measurement stored in
intermediate memory
Summary of Contents for J2KNpro Tech
Page 1: ...Operating Instructions ...