15. Diagnostics
15.1. Fault diagnostic
The ecom-J2KN
pro
TECH is able to
receive and to process information sent
via cable by the ecom-AK (read-out
head for digital firing automats).
In the main menu select the sub-menu
"Fault diagnosis"
and confirm with
<OK>
. The ecom-J2KN
pro
TECH tries to
get into contact with the
ecom-AK
(message:
„Searching“)
Once
the
connection is realized, the current
operation stand of the burner is shown
graphically
on
the
display.
The
operation stand can be recorded (max.
100 sec).
Press
<OK>
to start a new recording
phase (reset).
1/0
RM
OV
RZ
BV1
BV2
FL
Err
ON
Off
228
D K O 9 7 2 / 2 2
2.3
1.2
Ignition is
active
Flame
identified
Current
flame signal
Min. flame
signal
Model
name
Engine
on
Oil pre-warmer /
Air pressure
monitor is on
Operation
voltage
Valve 1
is on
Valve 2
is on
Recording of operation
stand (max. 100 sec):
1/0 = Continuous phase
RM = Fan motor
OV = Oil preheater
RZ = Ignition
BV1 = Valve 1st stage
BV2 = Valve 2nd stage
FL = Flame identified
Err = Disturbance
Reset = Start a new
recording (press
<OK>
)
ecom-AK
ecom-J2KN
pro
TECH
Cabel
connection
to AUX