Page 21
11. Averaging (continued)
4. Select
Printer
Select
No Value
to print only the final average values
Select
Each value
to print all recorded snapshots along with the
final average
Select
Each value of 2
to print every other recorded snapshot, etc.
5. Do not select
Store
. Please leave to default setting.
6. Select
Start Measurement
Mean value measurement has initiated
Press up/down to toggle between mean value and real-time results
7. After the
Meas. Time
has elapsed, press 6/Printer key to print
results
8. Press ESC, select
Mean Value
, and press F1 to quit mean value
calculation
12. Adjustments
Additionally to those
ecom-EN2-F
functions described previously,
various adjustments can be made in the instrument.
From the main menu, select the sub-menu
"Adjustments"
and con-
firm with
<Enter>
.
A selection of modifiable parameters,
adjustable according to the application,
is displayed.
Place the cursor on the desired line and
press
<Enter>
to call up or modify the
adjustment. The modifiable parameters
are:
Unit
(adjustment with
cursor keys
):
- Calculation of gas concentrations in:
- ppm
= volume concentration (parts per million)
- mg/m
3
= mass concentration per volume unit
- mg/kWh (undiluted) = mass concentration per power unit w/ O2
correction
- mg/MJ (undiluted)
= mass concentration per power unit w/ O2
correction
Units
Ref. O2
Fuel type
Air pressu
Set clock
Paper feed
Internal
Select
:
Adjustments
Summary of Contents for EN2-F