7.3 Analyzer startup
Press the red power button to turn on
the analyzer. The main menu is dis-
played with 6 (or 7) menu options:
- Gas analysis
: Perform gas analysis
(see
Chapter 8
)
- Averaging
: Perform averaging test
(see
Chapter 11
)
- Soot test
: Perform soot test/smoke dot test
(see
Chapter 10
)
- Data processing : Save snapshots to internal memory or perform
data logging (only displays if MM card is inserted)
(see
Chapters 6 & 14
)
- Adjustments
: Modify instrument settings
(see
Chapter 12
)
- Control
: Check operation state of instrument
(see
Chapter 13
)
- Diagnostics
: Only used with ECOM AK tool
To perform measurements, select
Gas analysis
and confirm with
<Enter>
. The instruments starts a 1- minute auto-zero phase and the
fuel types selection list is displayed. The following fuel types are
available:
Natural gas
Propane
Butane
Number 2 oil
Number 4 oil
Number 6 oil
Coal
Wood
North sea gas
Diesel oil
Fuel type
Natural gas
CO2max A1 B
11.7 0.37 0.009
Select:
Gas analysis
Averaging
Soot Test
Data Processing
Adjustments
Control
The probe must be in fresh air
when you start the analyzer!