ecom-CN
Page 21
The following advices will be of help for the daily check and mainte-
nance of single parts and assemblies:
Change fine dust filter (condensate trap profi version):
Screw off the cover. Release the filter and check the soiling state of
the filter. Change it once it has a grey colour in the gas flow area (ca.
number 3 on soot comparison scale). The safety filter should also be
replaced when the soiling degree corresponds to number 3 of said
comparison scale.
Change condensate pad (condensate trap profi version):
The condensate pad absorbs the humidity out of the sampled gas.
It stretches with increasing humidity volume and activates a contact
which switches off the pump (error message on display: „Empty wa-
ter trap!“) once the humidity content is exceeding. Screw off the
condensate trap. Release the knurled nut and place a new conden-
sate pad. Re-screw the condensate trap.
Condensate trap
Condensate pad
Knurled nut
Condensate trap with monitoring
(Profi version)
Safety filter
Fine dust filter
Summary of Contents for CN
Page 1: ...Operating Instructions ...