Ø25mm
A
OFF
230V
Pluto
1
2
3
Installation
Drill holes for the luminaire.
Part no. 595006-1, 595007-1
Switch off the power before installation!
Connect the quick connectors to the snap-in terminal block.
All
inputs on the snap-in terminal block must have a luminaire or jumper (
A
) installed in order for the
installation to work. This is so the circuit is closed.
Connect the driver unit to 230V.
Scan for more info
Push up the downlight without
the spacer ring for recessed
mounting, in the spacer ring for
surface mounting.
Switch on the power and test to
ensure the installation is correct.
3x
2m
30
12
80
30cm
2x
3x
2m
1x
30
(mm)
22,5
18
16
6x
38 1,8m
Power supply
220-240V AC
Power, luminaire
1 W
Total power
3.5 W
Enclosure
IP20
Luminous flux
50 lm
Brightness in determined direction
120 cd
Life span (L70)
40,000 h
Colour temperature
3,000K
Min/Max operating temperature
Ta -20 - +40˚C
SAFE INSTALLATION
Read these instructions before beginning the installation and hand them over to the user of the system. Only persons with the
requisite knowledge are to perform the installation or maintenance. If you lack this knowledge, contact a qualified electrician.
Make sure that the mains power is switched off before installation or maintenance
. Install the luminaire as described below. Posi-
tion the LED luminaire and driver unit far from heat sources and in a well ventilated area.
IP20
For dry envi-
ronments
CE-marked
Only for indoor
use
50 000x
Guaranteed
number of on/
off switching
230V
Connection
Must not be installed
directly in insulation
45°
Distribution
angle
Not dimmable
!
Elektro Elco AB, Tallvägen 5, SE-564 35 Bankeryd, Sweden | www.ecolite.se | UM005 | 201601