background image

Ø25mm

A

OFF

230V

Pluto

1

2

3

Installation

Drill holes for the luminaire.

Part no. 595006-1, 595007-1

Switch off the power before installation! 

Connect the quick connectors to the snap-in terminal block.

 

All 

inputs on the snap-in terminal block must have a luminaire or jumper (

A

) installed in order for the 

installation to work. This is so the circuit is closed.

 

Connect the driver unit to 230V. 

Scan for more info

Push up the downlight without 

the spacer ring for recessed 

mounting, in the spacer ring for 

surface mounting.

Switch on the power and test to 

ensure the installation is correct.

3x

2m

30

12

80

30cm

2x

3x

2m

1x

30

(mm)

22,5

18

16

6x

38 1,8m

Power supply

220-240V AC

Power, luminaire

1 W

Total power

3.5 W

Enclosure

IP20

Luminous flux

50 lm

Brightness in determined direction

120 cd

Life span (L70)

40,000 h

Colour temperature

3,000K

Min/Max operating temperature

Ta -20 - +40˚C

SAFE INSTALLATION 

Read these instructions before beginning the installation and hand them over to the user of the system. Only persons with the 

requisite knowledge are to perform the installation or maintenance. If you lack this knowledge, contact a qualified electrician. 

Make sure that the mains power is switched off before installation or maintenance

. Install the luminaire as described below. Posi-

tion the LED luminaire and driver unit far from heat sources and in a well ventilated area. 

IP20

For dry envi-

ronments

CE-marked

Only for indoor 

use

50 000x

Guaranteed 

number of on/

off switching

230V

Connection

Must not be installed 

directly in insulation

45°

Distribution 

angle

Not dimmable

!

Elektro Elco AB, Tallvägen 5, SE-564 35 Bankeryd, Sweden | www.ecolite.se | UM005 | 201601

en

III

Denotes the 

degree of 

protection of 

the luminaire

Denotes the 

degree of pro-

tection of the 

driver unit

Summary of Contents for Pluto

Page 1: ...tyrkan i bestämd riktning 120cd Livslängd L70 40 000h Färgtemperatur 3000K Min Max arbetstemperatur Ta 20 40 C SÄKER INSTALLATION Läs dessa instruktioner före installationen påbörjas och lämna den vidare till brukaren av anläggningen Endast personer med erforderlig kunskap skall utföra installationen eller underhåll Saknas denna kunskap kontakta en behörig elektriker Se till att spän ningen är frå...

Page 2: ... cd Life span L70 40 000 h Colour temperature 3 000K Min Max operating temperature Ta 20 40 C SAFE INSTALLATION Read these instructions before beginning the installation and hand them over to the user of the system Only persons with the requisite knowledge are to perform the installation or maintenance If you lack this knowledge contact a qualified electrician Make sure that the mains power is swi...

Page 3: ...stärke in einer bestimmten Richtung 120 cd Lebensdauer L70 40 000 h Farbtemperatur 3 000 K Min Max Arbeitstemperatur Ta 20 bis 40 C SICHERE INSTALLATION Lesen Sie diese Anweisungen vor Beginn der Installation und geben Sie sie an den Endanwender der Anlage weiter Nur Personen mit den erfor derlichen Kenntnissen dürfen die Installation oder Wartung durchführen Fehlen diese Kenntnisse wenden Sie sic...

Page 4: ...tyssä suunnassa 120cd Käyttöikä L70 40 000h Värilämpötila 3000K Min maks käyttölämpötila Ta 20 40 C TURVALLISUUSOHJEET Lue nämä ohjeet ennen asentamista ja luovuta ohjeet valaisimen seuraavalle käyttäjälle Vain riittävän taidon omaavat henkilöt saavat suorittaa asennuksen tai huollon Jos tätä ei ole ota yhteyttä valtuutettuun sähkömieheen Varmista että jännite on kytketty päältä ennen asennusta ja...

Page 5: ...ng 120 cd Levetid L70 40 000 t Fargetemperatur 3000 K Min maks arbeidstemperatur Ta 20 40 C SIKKER INSTALLASJON Les disse anvisningene før installeringen påbegynnes og gi dem videre til brukeren av anlegget Det er kun personer med nødven dig kunnskap som skal utføre installasjon eller vedlikehold Hvis denne kunnskapen mangler må en autorisert elektriker kontaktes Sørg for at spenningen er frakoble...

Page 6: ...cd Levetid L70 40 000h Farvetemperatur 3000K Min Maks arbejdstemperatur Ta 20 40 C SIKKER INSTALLATION Læs disse instruktioner før installationen påbegyndes og giv dem videre til brugeren af anlægget Det er kun personer med for nødent kendskab som må udføre installationen eller vedligeholdelsen Hvis dette kendskab mangler kontakt en autoriseret elek triker Sørg for at spændingen er slået fra før i...

Reviews: