Appendix B: Roof Attachment Methods
EcoFoot5D can be attached when required by seismic and uplift conditions or the Authority Having Jurisdiction
(AHJ). There are 3 methods of attachment that satisfy seismic and uplift requirements for Type 1 and Type 2
modules. Use the method indicated for the specific Fire Code Rating of the PV module. The Ballast Tray is not
required for attachment method for Modules with a Type 1 Fire Code Rating. The Ballast Tray is required for
attachment method for Modules with a Type 2 Fire Code Rating.
Attachment Methods
Seismic and Uplift Attachment
Seismic Attachment
Modules with Type 1 Fire Code Rating
Use Attachment with Strut
Modules with Type 1 & 2 Fire Code Rating
Use Attachment with Ballast Tray
Modules with Type 1 & 2 Fire Code Rating
Use Attachment with Ballast Tray and Strut
Attachment with Strut
Attachment with Strut – Components included in Kit
1
L-Bracket, 2”x3” –
Qty 3
2
Elevator Bolt, 1/4"-20 x 1-1/2”
Qty 2
2
Nut, Serrated Flange 1/4"-20
Qty 2
4
Nut, Strut 3/8"-16 x 1”
Qty 3
3
Nut, Serrated Flange 3/8"-16
Qty 1
6
Bolt, Serrated Flange 3/8"-16
Qty 3
Components Not Included in Kit
Strut, 1-5/8” x 1-5/8”
Roof Attachment (Flat Plate or
Station Anchor)
Tools Required
7/16” Deep Socket
9/16” Deep Socket
9/16” Open-End Wrench
Calibrated Torque Wrench
Torque Settings
8 ft-lbs for 1/4" fasteners, 14 ft-lbs. for 3/8” fasteners