Assembly and installation
Personnel:
n
Specialist
n
Service personnel
Protective equipment:
n
Protective gloves
n
Face protection
n
Safety shoes
The DG1-III is prepared for wall mounting with the product storage container placed on
the right-hand side.
If required, the product reservoir can also be placed on the left-hand side of the housing.
This involves moving the suction lance and the outlet for the power cable to the left-hand
side of the housing.
NOTICE!
The following connection and installation instructions constitute the
recommended procedure. However, the ambient conditions determine the
actual assembly and installation methods.
It is important to pay attention to conditions at the site of use.
Wall mounting
A mounting kit DG1-III with dowels and fixing screws as well as a drilling template are
included in the scope of delivery. If necessary, use special dowels and screws to fix the
unit.
1
2
3
4
5
6
7
8
8
9
10
Fig. 3: Wall assembly of DG1-III
1
Rawl plugs (4 x)
2
Rear panel of the housing
3
Screws (4 x)
4
Rawl plugs (2 x)
5
Screws (2 x)
6
Console for product container
7
Cover
8
external type plate
9
Stop screws (3 x)
10 Internal type plate