Set duration of detergent dispense per rack:
Range: 1-30 seconds, interval of 0.1 seconds
Default: 2.5 seconds.
Set frequency of detergent dosing:
Range: 1-10 racks, interval of 1 rack
Default: 1 rack
1
Adjust Dispensing: Conveyor Probe
Adjust Detergent
Adjust Rinse Aid
Adjust Third Product
Set detergent concentration:
Range: 1-100, increments of 1
Default: 50
Titrate machine sump to determine concentration.
Use Probe Diagnostics to determine when machine is at set point.
Machine is at set point when Temperature Compensated Value
equals Detergent Set Point.
See “Diagnostics & Troubleshooting --> Probe Diagnostics”
Adjust Detergent Set Point
1
Adjust Detergent
Adjust Rinse Aid
Adjust Third Product
Back
Set rinse pump speed:
Range: 8-30RPM, increments of 0.5RPM
Default: 15RPM
Prime the rinse line for 30 seconds at the programmed Rinse
Pump Speed.
Adjust Rinse Pump Speed
Rinse Pump Prime
Adjust Rinse Pump Speed
Rinse Pump Prime
01
Adjust Detergent
Adjust Rinse Aid
Adjust Third Product
Back
Set third product pump speed:
Range: 8-30RPM, increments of 0.5RPM
Default: 15 RPM
1
Adjust Detergent
Adjust Rinse Aid
Adjust Third Product
Back
Adjust Third Product Pump Speed
Logout
View Information
Adjust Dispensing
Diagnostics & Troubleshooting
Setup System
Set the initial detergent charge after machine fill
Range: 1-999 seconds, interval 1 second
Default: 37 Seconds
Set the rinse pump speed
Range: 8-30RPM, increments of 0.5RPM
Default: 15RPM
Set the rinse aid pump run time limit per rack:
Range: 0-50 seconds, increments of 1 second
Default: 15 seconds
Set the third product pump speed:
Range: 8-30RPM, increments of 0.5RPM
Default: 15RPM
Default product selection: None
Set the third product pump run time limit per rack:
Range: 0-50 seconds, increments of 1 second
Default: 15 seconds
50
15.0 RPM