18
i. Detergent: Product specific dispensing profiles and Out-of-Product
alarm notifications
ii. Rinse Additive: Product specific Out-of-Product alarm signal input and
Out-of-Product alarm notifications
iii. Third Product: Product specific Out-of-Product alarm notifications
c. Adjust Dispensing Parameters: The dispensing parameters are set in the
“Adjust Dispensing” menu. Only the parameters appropriate to the
machine mode chosen will be made available.
i. Detergent:
1. Detergent Set Point
a. Detergent concentration should be set by titrating the wash tank,
then adjusting the Detergent Set Point up or down as needed to
reach the desired concentration. This value ranges from 1-100 in
increments of 1 with a default setting of 50.
2. Initial Detergent Charge (Timed Mode Only)
a. Set the amount of time that the detergent will feed after the initial
feed of the dishmachine. This value ranges from 1-999 seconds in
increments of 1 second with a default setting of 10 seconds.
3. Detergent Dose Interval (Timed Mode Only)
a. Set the frequency of the Detergent Dose. This value ranges from
1-10 racks in intervals of 1 rack, with a default of 1 rack.
4. Detergent Dose Time (Timed Mode Only)
a. Set the length of detergent dispense time per the Detergent Does
Interval. This value ranges from 1-30 seconds in intervals of 0.1
seconds, with a default setting of 2.5 seconds.
ii. Rinse Additive / Third Product
1. Pump delay (Door Mode only)
a. Set the delay time for starting the rinse /third product pump
after receiving a qualified wash signal. This value ranges from
0-30 seconds in intervals of 1 second with a door machine default
of 2 seconds.
2. Pump Limit:
a. Set the maximum time that the rinse pump is allowed to run. This
value ranges from 0-50 seconds in increments of 1 second, with a
default of 10 seconds.
3. Pump Speed
a. Set the rinse/third product pump speed. This value ranges from
8-30 RPM in increments of 0.5 RPM, with a default of 15 dsRPM.
d. Alarming Parameters
i. Alarm Volume
1. Set the volume of the alarm notification. This value ranges from
0 – 10 with intervals of 1.
ii. Detergent Alarm Delay
1. Set the delay time before the controller activates the Detergent Out
of Product alarm. This setting monitors the time that the detergent
solenoid valve is open while being below the Detergent Set Point.
This value ranges from 5-1000 seconds in intervals of 5 seconds with
a default of 300 seconds.
iii. Wash Tank Change-Out
1. Set the number of racks required to activate the Change Wash Tank
alarm. This value ranges from 0-950 racks in increments of 25 racks
with a default of 250 racks.
iv. Alarm Mute Time
1. Set the duration of a muted alarm when the “Mute Alarm” button
is pressed during an active alarm. Once the inputted time expires
the screen Apex2 controller screen will revert from yellow back to
red and the audible alarm will re-sound.
Figure 5.3
Figure 5.4
Figure 5.5
Figure 5.6
Figure 5.7