Ecolab 9223-1070 Installation And Operation Manual Download Page 29

27

8561-4055 

Plumbing Fitting 

1/4" T x 1/4" MNPT Fitting for Pressure Reducing Valve 

8563-4350 

Plumbing Fitting 

Elbow 1/4" T x 1/4" MNPT Fitting for Solenoid Valve 

9200-1034 

Sensor 

Apex2 Rinse Aid Out-Of-Product Signal Wire for Retrofits 

9230-2013 

Sensor 

Inductive Probe 12' 

9230-2014 

Sensor 

Inductive Probe 24' 

9230-2054 

Sensor 

Inductive Probe 50' 

9230-1017 

Sensor 

Liquid Out-of-Product Sensor 

9230-1016 

Sensor 

Rinse Thermistor 

9204-2027 

Plumbing 

24V DC Solenoid Valve Diaphragm Replacement 

8501-5154 

Miscellaneous 

1/8" Rinse Aid Tubing (1,000') 

8560-5129 

Miscellaneous 

1/4" Rinse Aid Pump Jaco Head Fitting 

9266-2220 

Miscellaneous 

5/8" OD Mayon Tubing (25') 

8330-0541 

Miscellaneous 

1/2" Liquid Tight Conduit (100') 

9204-2084 

Plumbing 

24V DC Solenoid Valve Guide Tube / Bell Housing 

9230-1026 

Miscellaneous 

Apex2 I/O Box Mounting Bracket, Stainless Steel 

9223-1068 

Installation Kit 

Apex Detergent Dispenser White 

9223-1069 

Installation Kit 

Apex Rinse Additive Dispenser White 

9223-1054 

Installation Kit 

Apex Pot and Pan Soak Hydraulic White 

9223-1055 

Installation Kit 

Apex Pot and Pan Soak Electromatic White 

9223-1052 

Installation Kit 

Apex Presoak Hydraulic White 

9223-1053 

Installation Kit 

Apex Presoak Electromatic White 

9223-1048 

Installation Kit 

Apex Solid Sanitizer White 

9223-1049 

Installation Kit 

Apex RTU Manual Detergent White 

 

Summary of Contents for 9223-1070

Page 1: ...Apex2 Installation and Operation Manual 370 Wabasha Street N St Paul MN 55102 www ecolab com 2012 Ecolab Inc All rights reserved 43569 5400 0112 Part No 9223 2253...

Page 2: ...tional Pressure Switch 9 New Install Wiring 10 Machine Signals and Apex2 Power 10 11 I O Board Connections 12 Sealing Block 13 Retrofit Kit Converting Apex to Apex2 14 Apex Rinse Additive Signal Wire...

Page 3: ...ctionable and intuitive information to the customer and creates an efficient interface for Ecolab sales representatives This control system will help the customer achieve superior results with improve...

Page 4: ...pump Squeeze tubes with different delivery rates for high or low volume installations Variable speed DC motor 8 30 RPM Adjustable run time and start delay on door machines Optional Pressure Switch fo...

Page 5: ...cm IO Box Dimensions Height 9 2 23 4 cm 14 7 37 3 cm w door open Width 10 7 27 1 cm one pump Depth 5 5 14 0 cm Electrical Requirements The Apex2 Controller operates within the following Incoming Powe...

Page 6: ...tory to electrically connect this input Sanitizer Lid Switch that prevents sanitizer pump from running while the lid is open Note This is an optional feature used with certain external dispensers A ju...

Page 7: ...e Thermistor Apex2 Retrofit Kit 9223 1071 Contents Apex2 User Interface Module Apex2 I O Enclosure Cover I O Board assembly Inductive Probe 12 RS 485 Communication Cable Rinse Thermistor Apex2 New Cus...

Page 8: ...e only the wall mount bracket Note Avoid mounting the controller in areas near the dish pre scrap area and the rinse section of the dish machine due to excessive water heat and food soil Connect RS 48...

Page 9: ...rged particularly on shallow tank machines Before drilling the hole in the wash tank identify and avoid any obstructions both inside and outside the wash tank Installations Steps 1 Drill Cut a 7 8 22...

Page 10: ...for separate installations of the rinse injection line and the thermistor use the supplied 1 8 FNPT x 1 8 MNPT brass bushing ONLY OR b If the thermistor and rinse line must be installed in the same p...

Page 11: ...to be installed The rinse injector will then be activated when the switch closes from the pressure created by the flow of the final rinse water 1 Locate hexagon feature on the bottom of the I O enclos...

Page 12: ...power the electrical overcurrent protection and grounding connections must comply with the applicable portions of the National Electric Code ANSI NFPA 79 latest edition and or other local electrical...

Page 13: ...or pressure switch connections must be connected for all installations Main Power Connect Blue and Brown wires to constant voltage source Connect Green with Yellow stripe wire to verified earth groun...

Page 14: ...e Thermistor Detergent Dispenser Lid Switch Pressure Switch optional 12 1 8 APEX DETERGENT LID SWITCH SANITIZER MOTOR PRESSURE SWITCH OPTIONAL DETERGENT VALVE APEX RINSE MAIN POWER RED BLK BLK S BRN B...

Page 15: ...al noise interference After making wire connections install the cable sealing block inside the Apex2 I O Enclosure 1 Place sealing block underneath wires and align the guides into position See figure...

Page 16: ...ir 3 Connect the supplied grey wire to the male connector of the white wire 4 Route the grey wire out the bottom of the rinse dispenser to the Apex2 I O Enclosure Note Leave the remaining white termin...

Page 17: ...nclosure causing the cover to unsnap from the stainless steel hinge pin b Do not throw the Apex board into the garbage The board must be disposed of properly c Ship to Ecolab Hwy 251 Rockton Rd South...

Page 18: ...tall the supplied 4 pin jumpered Phoenix connector in the Rinse Lid Switch and San Lid Switch location on the Apex 2 I O board f Connect the Inductive Probe to the Apex2 I O board Wrap excess cable ou...

Page 19: ...mp runs at the set rinse pump speed for the programmed Rinse Pump Limit or until the rinse input is turned off whichever comes first ii Door Machine Timed Mode 1 Door machine functionality such as rac...

Page 20: ...2 5 seconds ii Rinse Additive Third Product 1 Pump delay Door Mode only a Set the delay time for starting the rinse third product pump after receiving a qualified wash signal This value ranges from 0...

Page 21: ...19 v Alarm Priority...

Page 22: ...ower lights See I O Board diagram in the electrical section for further information Can the Apex2 controller play videos Yes training videos are located in the Help screen from the main screen and ala...

Page 23: ...unication Light see page 16 If not blinking disconnect dish machine power for 10 seconds at main breaker and reconnect If problem remains replace I O Board Apex2 Controller does not feed Detergent 1 S...

Page 24: ...ignal on the I O board and check rinse pump delay setting If motor does not operate check for DC voltage at rinse pump terminals on I O Board During Rinse Pump Test if voltage is greater than 1 VDC an...

Page 25: ...place pump squeeze tube 3 Check injection fitting for obstruction clean or replace as needed 4 Check squeeze tube for wear and replace if needed Rinse Aid Pump will not prime 1 Check tubing connection...

Page 26: ...ded with new squeeze tube inside the pump housing It may be beneficial to use a screwdriver to rotate the roller assembly clockwise to assist in the placement of the squeeze tube 7 Lubricate the new s...

Page 27: ...3 2196 Electrical Apex2 I O Board 6 8349 4007 Electrical Apex2 Power Supply 7 9200 0027 Electrical Apex2 RS 485 Terminating Plug 8 8374 0357 Electrical 24VDC Rinse Pump Motor 9 9200 1077 Miscellaneous...

Page 28: ...llaneous Apex2 I O Box Cable Seal 9202 2555 Miscellaneous Apex2 I O Box Ecolab Badge 9200 0012 Miscellaneous Apex2 RS 485 Cable seal for retrofits 9200 2115 Plastic Part Apex2 I O Box Cover 9200 2132...

Page 29: ...us 1 4 Rinse Aid Pump Jaco Head Fitting 9266 2220 Miscellaneous 5 8 OD Mayon Tubing 25 8330 0541 Miscellaneous 1 2 Liquid Tight Conduit 100 9204 2084 Plumbing 24V DC Solenoid Valve Guide Tube Bell Hou...

Page 30: ...Pump Limit Adjust Third Product Pump Start Delay 15 0 RPM Set the rinse aid pump run time limit per rack Range 0 50 seconds increments of 1 second Default 15 seconds Adjust Rinse Pump Speed Adjust Ri...

Page 31: ...e line for 30 seconds at the programmed Rinse Pump Speed Adjust Rinse Pump Speed Adjust Rinse Pump Limit Adjust Rinse Start Delay Adjust Pump Prime Set the rinse aid pump run time limit per rack Range...

Page 32: ...tergent Adjust Rinse Aid Adjust Third Product Back Set rinse pump speed Range 8 30RPM increments of 0 5RPM Default 15RPM Prime the rinse line for 30 seconds at the programmed Rinse Pump Speed Adjust R...

Page 33: ...Valve Run Time Adjust Detergent Dose Interval Adjust Initial Detergent Charge 1 Adjust Detergent Adjust Rinse Aid Adjust Third Product Back Set rinse pump speed Range 8 30RPM increments of 0 5RPM Def...

Page 34: ...gent Adjust Rinse Aid Adjust Third Product Back Set rinse pump speed Range 8 30RPM increments of 0 5RPM Default 15RPM Prime the rinse line for 30 seconds at the programmed Rinse Pump Speed Adjust Rins...

Page 35: ...d Switch Position Machine Signal Interface Diagnostics Out of Product Alarms Dispensing Tests Probe Diagnostics Detergent Inactive Rinse Aid Inactive Third Product Inactive Press start to turn the det...

Page 36: ...1 Product Selection Language Set Up Alarms Unit of Measurement Reset to Default Settings Set Tablet Values Date Time Machine Setup Set date and time on controller 1 Product Selection Language Set Up A...

Page 37: ...activations 1 Rack Counts Diagnostic Data Alarm Data I O Board Information Controller Board Information Apex 2 controller Serial number build date and software version 1 Rack Counts Diagnostic Data Al...