The deterioration of the stove parts by a lack of cleaning involves the loss of the two-year warranty offered
by
ECOFOREST
(see warranty section).
DAILY CLEANING WHEN THE STOVE IS COLD.
5.1.
Heat Exchanger.
Pull the drawers of the rake-this shall be done while the glass door closed in order to reach the ash inside the
stove. This shall be done
every day
when the stove is cold.
For Ecoaire model (
drawing 17
), Ecoaire Insert y Eco II (
drawing 18
), you can Access to the drawers of the
rake opening the trim grill.
Trim grill.
Drawers of the rake.
Drawing 17
Trim grill.
Drawers of the rake.
Drawing 18
In Eco II and Atenas models, a greater weekly cleaning must be made on the heat exchanger. As shown in
drawing 19
(Eco II) to gain better access to the exchanger and clean it perfectly, you have to push up the top
plate of the fireplace, to disengage the tabs which secure it to the centre plate and pull it. When finished, put
back the top plate being sure that the tabs are properly seated.
Drawing 19
Top plate of the fireplace.
Heat exchanger tubes.
Summary of Contents for Atenas
Page 1: ......
Page 111: ...110 9 MEDIDAS MEASURES MESURES MISURES MEDIDAS ECOAIRE EC UNE EN 14785...
Page 112: ...111 10 MEDIDAS MEASURES MESURES MISURES MEDIDAS ECOAIRE INSERT EE UNE EN 14785...
Page 114: ...113 12 MEDIDAS MEASURES MESURES MISURES MEDIDAS ECO II INSERT EAM UNE EN 14785...
Page 116: ...115 14 MEDIDAS MEASURES MESURES MISURES MEDIDAS ATENAS VR 2012 UNE EN 14785...