34
Drawing 14
Place the magnet connection base with the antenna where appropriate. The antenna’s LED should be easily
visible. When possible, avoid the presence of metal sheets around the antenna as the wifi signal might be distorted.
Wifi upper view.
Wifi plan view with no metal objects around.
ASSEMBLING OF THE SAFETY THERMOSTAT IN INSERT MODELS.
If the stove that you have is an Eco I Insert or Eco II, you must fix the safety thermostat to the panels of the
insert model. These panels have a hole, through which you must insert the thermostat (
) according to
drawing 15,
and fix it to the socket with a nut (
) and finally you screw the stopper (
). The stove used in drawings is an EcoII
model, showing the final result in the
drawing 16.
For Ecoaire you must do the same process.
Drawing 15
Drawing 16
5.
CLEANING AND MAINTENANCE.
To ensure the correct operation of your stove, the following cleaning and maintenance operations are
necessary at the indicated frequency. The stove must always be cold.
CPU.
USB female connectors.
Magnet
connection
base
male
USB
connector.
Summary of Contents for Atenas
Page 1: ......
Page 111: ...110 9 MEDIDAS MEASURES MESURES MISURES MEDIDAS ECOAIRE EC UNE EN 14785...
Page 112: ...111 10 MEDIDAS MEASURES MESURES MISURES MEDIDAS ECOAIRE INSERT EE UNE EN 14785...
Page 114: ...113 12 MEDIDAS MEASURES MESURES MISURES MEDIDAS ECO II INSERT EAM UNE EN 14785...
Page 116: ...115 14 MEDIDAS MEASURES MESURES MISURES MEDIDAS ATENAS VR 2012 UNE EN 14785...