![ECOFOREST Atenas Installation And Maintenance Manual Download Page 29](http://html1.mh-extra.com/html/ecoforest/atenas/atenas_installation-and-maintenance-manual_2354364029.webp)
28
Drawing 2
MATERIAL REQUIRED FOR INSALLATION
.
MATERIAL
COMPLIANCE
PARTICULARS
Stainless steel pipe (AISI 316L).
OBLIGATORY
ALL.
Aluminum, galvanized or iron
pipe.
PROHIBITED
ALL.
Insulated double wall pipe.
OBLIGATORY
Proximity to flammable materials.
Insulated double wall pipe.
OBLIGATORY
[he gas outlet goes through or near flammable
material.
Insulated double wall pipe.
OBLIGATORY
Insert stoves. See figure 4.
Insulated double wall pipe.
RECOMMENDABLE
Relative ambient humidity ≥ 60%.
Insulated double wall pipe.
RECOMMENDABLE
Installation in a public facility.
Insulated double wall pipe.
RECOMMENDABLE
Potentially accessible to children or people with
mental, physical or sensory disabilities.
Clamp union.
OBLIGATORY
Install the exhaust spiral and gas outlet pipes,
thereby preventing anyone from disassembling or
moving the stove or pipe without tools.
Pipe anchors.
OBLIGATORY
Install the pipe, thereby preventing anyone from
disassembling or moving the stove or pipe without
tools.
Aluminium belt and silicone of
high temperature (300°C).
RECOMMENDABLE
If the pipe is not equipped with sealing rings
Ventillation grills.
OBLIGATORY
Insert stoves. See figure 4.
LOCATION AND SAFETY DISTANCES.
4.10.
Do not install the stove in a sleeping room.
4.11.
Install a fire protection between the ground and the stove if the floor is a combustible material.
4.12.
Security distances should be respected when the stove is installed in spaces where materials around it, be it
the construction material itself, the fuel or any other type of materials, are likely to be flammable. Granting a
better access to the stove for future maintenance or repair work is also worth considering.
Summary of Contents for Atenas
Page 1: ......
Page 111: ...110 9 MEDIDAS MEASURES MESURES MISURES MEDIDAS ECOAIRE EC UNE EN 14785...
Page 112: ...111 10 MEDIDAS MEASURES MESURES MISURES MEDIDAS ECOAIRE INSERT EE UNE EN 14785...
Page 114: ...113 12 MEDIDAS MEASURES MESURES MISURES MEDIDAS ECO II INSERT EAM UNE EN 14785...
Page 116: ...115 14 MEDIDAS MEASURES MESURES MISURES MEDIDAS ATENAS VR 2012 UNE EN 14785...