Risk of air blast!
Continuously check CO, CO2 and soot emissions when adjusting the output of
the burner. Optimise combustion values in the event of CO formation. CO must
not exceed 50 ppm.
Start up
- Setting data table - Air regulation
The settings above are
basic settings.
These adjustment values are normally
suitable for commissioning the burner.
These values have been determined in
our test labs and are useful for the first
switch-on as final setting must be done
using a combustion analyzer.
Favourable combustion values can be
achieved using the following nozzles:
DANFOSS H÷S 80°÷60°
DELAVAN W 60°
STEINEN S 60°
NOZZLE PUMP OUTPUT FIRING HEAD SETTING AIR DAMPER SETTING
gph spry bar kg/h Pos. Pos.
0,50 60°S 12 2 0 3
0,60 60°S 12 2,4 0,5 4
0,65 60°S 12 2,7 0,5 5
0,75 60°S 10 2,94 1 4
0,85 60°S 12 3,5 3 8
1,00 60°S 12 4,35 4 10
1,00 60°S 12 4,35 1 4
1,10 60°S 12 4,5 1 5,5
1,25 60°S 12 5 2 6,2
1,35 60°S 12 5,6 2,5 7,3
1,50 60°S 10 5,8 1 4
1,65 60°S 12 7 4 9,2
1,75 60°S 12 7,6 4,5 10,5
1,50 60°S 12 6,2 0 2
1,65 60°S 12 7 1 3,5
1,75 60°S 12 7,6 2 5
2,00 60°S 12 8,3 3 7
2,25 60°S 12 9,3 3,5 8,5
2,50 60°S 12 10,4 4 9,5
2,75 60°S 12 11,5 4,5 10,5
MAX 4
MAX 12
MAX 8
+
-
A
Air damper setting (A).
To act on the screw in figure:
• to increase output, turn screwdriver
clockwise
• to reduce output, turn screwdriver
counterclockwise
Air damper setting (A1).
To adjust air flow , loosen the two screw B
and turn the air damper as required.
Tighten the screw B.
Firing head setting (B).
To act on the screw in figure:
• turn Allen key till you reach the
requested value (index 0-4,5).
MAX 8-12
+
-
+
-
B
MAX 4-8-12
MAX 4