Important notes
MAX P 35-45 AB burners are designed for
the combustion of domestic fuel oil EL in
accordance with EN267 standards.
Assembly, commissioning and
maintenance must be carried out only by
authorised specialists and all applicable
guidelines and regulations must be
observed.
Burner description
MAX P 35-45 AB are two-stage, fully-
automatic monoblock-type burner. It is
suitable for use, within its range of
performance, with boilers complying with
EN 303 or hot-air generators in line with
DIN 4794, DIN 30697 or EN 621.
Use for any other application requires the
approval of Ecoflam.
The following standards should be
observed in order to ensure safe,
environmentally sound and energy-efficient
operation:
EN 226
Connection of vaporising oil and forced
draught gas burners to the heat generator.
EN 60335-2
Safety of electrical equipment for domestic
use.
Installation location
The burner must not be operated in rooms
containing aggressive vapours (e.g. spray,
perchloroethylene, hydrocarbon
tetrachloride, solvent, etc.) or tending to
heavy dust formation or high air humidity.
Adequate ventilation must be provided at
the place of installation of the furnace
system to ensure a reliable supply with
combustion air.
Variations may arise as a result of local
regulations.
We can accept no warranty liability
whatsoever for loss, damage or injury
caused by any of the following:
- Inappropriate use.
- Incorrect assembly or repair by the
customer or any third party, including the
fitting of non-original parts.
Provision of the system and the
operating instructions
The firing system manufacturer must
supply the operator of the system with
operating and maintenance instructions on
or before final delivery. These instructions
should be displayed in a prominent
location at the point of installation of the
heat generator, and should include the
address and telephone number of the
nearest customer service centre.
Notes for the operator
The system should be inspected by a
specialist at least once a year. It is
advisable to take out a maintenance
contract to guarantee regular servicing.
Ecoflam burners have been designed and built in compliance with all current regulations
and directives.
All burners comply to the safety and energy saving operation regulations within the standard
of their respective performance range. The quality is guaranteed by a quality and management
system certified in accordance with ISO 9001:2008.
420010492200
EN
Overview
Technical data
3
Working fields
4
Dimensions
5
Contents
Index
6
General warnings
6
Burner description
7
Function
General safety functions
8
TCH 2xx control box
9-10-11
Terminal allocation chart 230 Volt connection
12
Terminal allocation chart low voltage connections
13
Oil burner pump
14
Installation
Burner assembly
15
Electrical connection - Checks before commissioning
16
Oil feeding and suction line - Setting data table
17
Start up
Pre-setting without flame
18
Adjusting burner output - Oil pressure regulation
19
Setting the flame
20
Operating mode
21
Saving the adjustment values in the display
22
Service
Maintenance
23-24
Troubleshooting
25
Fault diagnosis menu
26
Operating statistics menu
27
Overview
Electrical diagrams
116-119
Spare parts list
120-121
Contents
Conformity declaration
122
6
Summary of Contents for 3140420
Page 123: ...420010492200 EN IT FR ES RU 123 ...
Page 124: ......