service:

MANUAL INITIATED ELECTRONICS DIAGNOSTIC

. . . . . . . . . . . . . . . . . . . . . . . . . .

1.

Press and hold the Select

button until the display shows

“000--- ---” to enter diagnostics.

The letter (P) and dash(es) in-

dicate POSITION switch op-

eration. The letter appearing

means the switch is closed;

the dash means the switch is

open.

Use the

Touch---Hold

button to manually advance

the valve into each cycle and check correct switch

operation.

CORRECT

SWITCH

DISPLAYS

VALVE CYCLE STATUS

-- --

Valve in service, backwash or fast

rinse position.

--

P

Valve rotating from one position to

another.

While in this diagnostic screen, the following infor-

mation is available and may be beneficial for various

reasons. This information is retained by the comput-

er from the first time electrical power is applied to the

face plate.

Press the Up button to display

the number of days this face

plate has had electrical power

applied.

Press the Down button to dis-

play the number of recharges

initiated by this face plate

since the model code number

was entered.

2.

Press the Select button and

hold in 3 seconds until a mod-

el code appears in the display.

For correct filter operation, the model code number

must be HAIIF.

To reset the code, press the Up or Down button until

the correct number shows.

3.

Press Select to return the present time display. If

the code was changed, make ALL the timer settings,

pages 11 and 12.

"

OTHER SERVICE

UNFILTERED WATER BYPASS (unfiltered water “bleeds” into filtered water supply.

1.

Defective rotor and disc, seal or wave washer (see pages 22 and 23).

2.

Missing or defective o--ring(s) at resin tank to valve connection (see pages 20 and 21).

"

AUTOMATIC ELECTRONIC DIAGNOSTICS

The face plate has a self diagnostic function for the electrical systems (except input power). The faceplate

monitors the electronic components and circuits for correct operation. If a malfunction occurs, an error code

appears in the faceplate display.

POSSIBLE DEFECT

CODE

MOST LIKELY

----------------------------------------------------------------------------------------------

LEAST LIKELY

Err 01 Err 02

Err 03 Err 04

wiring harness or connection to position switch / switch / valve defect causing high torque / motor

inoperative

Err 05

faceplate

PROCEDURE FOR REMOVING ERROR CODE FROM FACEPLATE:

1. Unplug transformer-------- 2. Correct defect-------- 3.

Plug in transformer-------- 4. Wait for 8 minutes. The error code will return if the defect was not corrected. Press and hold the TOUCH--
HOLD button for 3 seconds as an alternate way to clear an error code.

Summary of Contents for NS AIIF2

Page 1: ...d high flow 1 valve MODEL NS AIIF2 Installation D D Operation D D Maintenance D D Repair Parts D D Designed Engineered Assembled in the U S A ECODYNE WATER CONDITIONING 1890 Woodlane Drive Woodbury MN...

Page 2: ...to you at no cost if our repair department determines it to be defective under the terms of the warranty This warranty gives you specific legal rights and you may have other rights which vary from sta...

Page 3: ...air If it is backwashed before the air is removed the valve may become plugged with birm particles or particles may be flushed to the drain TABLE OF CONTENTS PAGE NO Warranty Safety Guides 2 Unpackin...

Page 4: ...al Filter Timer 24V 60 Hz Air Pump 120V 60 Hz Some feed water with high iron concentrations or low pH may require limited service flows or a neutralizer filter be fore the system TABLE 1 pH 6 5 7 0 7...

Page 5: ...VALVE IN BYPASS AND ADVANCE FILTER VALVE TO BACKWASH BEFORE DISASSEMBLY DRAIN HOSE 5 8 I D minimum to floor drain 5 gal min FIGURE 1 To Outlet Relay Box VENT TUBE 20 ft coil excess tube do not cut To...

Page 6: ...e joint compound D primer D solvent cement D LEAD FREE solder and flux MATERIALS YOU WILL NEED H bypass valve or 3 valves H pipe and fittings as required H 5 8 I D minimum drain hose either standard g...

Page 7: ...Water Quality Association for disinfecting On some water supplies they suggest periodic sanitizing 1 INSTALL INCLUDED SINGLE BYPASS VALVE and or INSTALLATION ADAPTORS NOTE All fittings are in the part...

Page 8: ...tings from the main water pipe or from bypass valves installed in step 3 to the filter inlet and outlet copper tubes BE SURE UNFILTERED WATER SUPPLY PIPE GOES TO THE FILTER INLET SIDE Trace the water...

Page 9: ...ads NOTE Flexible drain hose is not allowed in all localities See option on page 6 b Route the hose to the drain point standpipe laundry tub floor drain etc as typically shown in Figure 1 Affix the en...

Page 10: ...orresponding connectors of the wire harness located near the solenoid under the top cover Route the wiring through the clip in the bottom cover as shown in Figure 2 12 CONNECT AIR PUMP a Fasten the ai...

Page 11: ...TIME OF DAY If the words PRESENT TIME do not show in the display press the SELECT button until they do Press the UP or DOWN buttons to set the present time Up moves the display ahead down moves the t...

Page 12: ...l fide set the filter to recharge more often than the table above shows Press the SELECT button to set and advance to the next set up screen SET RECHARGE TIME The default setting is 12 00 AM This is a...

Page 13: ...ater flow has stoped D Make sure the ball valve on the neck adaptor is open See Figure 10 D Make sure the solenoid vent is open when the air pump is running D Make sure the vent tube is held securely...

Page 14: ...r supply to the filter use the plumbing bypass valve s feature POWER OUTAGE MEMORY If electrical power to the timer is interrupted the memory built into timer circuitry keeps all settings for several...

Page 15: ...lter through the adaptor The air oxidizes the iron The oxidized iron is then mechanically filtered by the filter mineral bed The solenoid valve allows excess air to vent from the tank SERVICE BACKWASH...

Page 16: ...16 WATER FLOW PATHS THROUGH VALVE FIGURE 11 SERVICE CYCLE FIGURE 12 BACKWASH CYCLE FLOW PLUG FIGURE 13 FAST RINSE CYCLE...

Page 17: ...ank This supplies oxygen that aerates the water and oxidizes iron manganese and hydrogen sulfide generating particles The vent solenoid is opened during this time permitting oxygen depleted air to esc...

Page 18: ...ton to move filter into fast rinse Again look for fast drain flow To return filter to service press the Touch Hold button NOTE While in manual advance the time display will automatically return to the...

Page 19: ...ay For correct filter operation the model code number must be HAIIF To reset the code press the Up or Down button until the correct number shows 3 Press Select to return the present time display If th...

Page 20: ...0 11 12 6 5 Valve Assembly see pages 22 23 1 WARNING FILTER TANK CONTAINS AIR TO RELIEVE PRES SURE PUT BYPASS VALVE IN BYPASS AND ADVANCE FILTER VALVE TO BACKWASH BEFORE DISASSEMBLY 26 15 18 17 20 14...

Page 21: ...9 Tank Base KEY NO PART NO DESCRIPTION 7112963 Distributor O ring Kit includes Key Nos 14 16 14 O ring 13 16 I D x 1 1 16 O D 15 O ring 2 7 8 I D x 3 1 4 O D 16 O ring 2 3 4 I D x 3 O D 17 7310278 Ada...

Page 22: ...PAIR PARTS 50 51 53 52 54 55 56 57 58 59 60 61 66 67 62 63 64 68 69 75 76 65 80 81 84 85 86 cross section view seal wear strip flow plug assembly assembled view 78 77 73 88 74 79 83 82 82 72 70 71 87...

Page 23: ...00 Rotor Disc 68 7171187 Plug Drain Seal 69 7129889 Spring 70 7089306 Clip 4 req KEY NO PART NO DESCRIPTION 71 7271204 Installation Adaptor 1 2 req 72 7311127 O ring 1 1 16 x 1 5 16 4 req 7290931 Turb...

Page 24: ...ECODYNE WATER CONDITIONING 1890 Woodlane Drive Woodbury MN 55125...

Reviews: