PROGRAMMING THE FACEPLATE TIMER

SUGGESTED RECHARGE DAYS

The filter must recharge to clean iron out of the filtering mineral. How often recharge is needed depends on

two things.

1.

The parts per million (PPM) of iron in your water supply and;

2.

The number of people that live in your house.

To use the table, find the ppm iron in your water supply across the top of the table. Read down this column,

and across from the number of people in the household. At the intersecting point, the suggested days to

recharge are shown. Set the recharge days on the timer.

Number of people

in household

Iron (parts per million)

1 -- 2

3 -- 4

5 -- 7

8 -- 20

1

4 days

3 days

2 days

1 day

2

4 days

3 days

2 days

1 day

3

4 days

3 days

1 day

1 day

4

3 days

2 days

1 day

1 day

5

3 days

2 days

1 day

1 day

6

2 days

1 day

1 day

1 day

7

2 days

1 day

1 day

1 day

NOTE:

If the water supply has high turbidity (sand, silt, sediments, etc.), manganese or hydrogen sul-

fide, set the filter to recharge more often than the table above shows.

Press the

SELECT button to set and advance to the next set up screen.

"

SET RECHARGE TIME

The default setting is 12:00 AM. This is a good time if you have a water softener or another filter installed, the

recharge time should be offset to assure adequate water flow and pressure. For example, set the filter to start

backwash at 12:00 AM, or 4:00 AM, if the water softener is set to begin recharge at 2:00 AM.

If a change is needed, use the

UP or

DOWN buttons to set time.

Press the

SELECT button to set and return to the normal run display.

THE INSTALLATION AND PROGRAMMING STEPS ARE COMPLETE

NOTE: After you have completed all preceding instructions, your house water supply is filtered immediately.

However,

your water heater is filled with unfiltered water

and, as hot water is used, it will refill with filtered

water. When all the water is replaced in the water heater, all water will be filtered. If you want totally filtered water

immediately, drain the water heater until the water runs cold.

Use extreme care as the hot water could cause

severe burns.

Summary of Contents for NS AIIF2

Page 1: ...d high flow 1 valve MODEL NS AIIF2 Installation D D Operation D D Maintenance D D Repair Parts D D Designed Engineered Assembled in the U S A ECODYNE WATER CONDITIONING 1890 Woodlane Drive Woodbury MN...

Page 2: ...to you at no cost if our repair department determines it to be defective under the terms of the warranty This warranty gives you specific legal rights and you may have other rights which vary from sta...

Page 3: ...air If it is backwashed before the air is removed the valve may become plugged with birm particles or particles may be flushed to the drain TABLE OF CONTENTS PAGE NO Warranty Safety Guides 2 Unpackin...

Page 4: ...al Filter Timer 24V 60 Hz Air Pump 120V 60 Hz Some feed water with high iron concentrations or low pH may require limited service flows or a neutralizer filter be fore the system TABLE 1 pH 6 5 7 0 7...

Page 5: ...VALVE IN BYPASS AND ADVANCE FILTER VALVE TO BACKWASH BEFORE DISASSEMBLY DRAIN HOSE 5 8 I D minimum to floor drain 5 gal min FIGURE 1 To Outlet Relay Box VENT TUBE 20 ft coil excess tube do not cut To...

Page 6: ...e joint compound D primer D solvent cement D LEAD FREE solder and flux MATERIALS YOU WILL NEED H bypass valve or 3 valves H pipe and fittings as required H 5 8 I D minimum drain hose either standard g...

Page 7: ...Water Quality Association for disinfecting On some water supplies they suggest periodic sanitizing 1 INSTALL INCLUDED SINGLE BYPASS VALVE and or INSTALLATION ADAPTORS NOTE All fittings are in the part...

Page 8: ...tings from the main water pipe or from bypass valves installed in step 3 to the filter inlet and outlet copper tubes BE SURE UNFILTERED WATER SUPPLY PIPE GOES TO THE FILTER INLET SIDE Trace the water...

Page 9: ...ads NOTE Flexible drain hose is not allowed in all localities See option on page 6 b Route the hose to the drain point standpipe laundry tub floor drain etc as typically shown in Figure 1 Affix the en...

Page 10: ...orresponding connectors of the wire harness located near the solenoid under the top cover Route the wiring through the clip in the bottom cover as shown in Figure 2 12 CONNECT AIR PUMP a Fasten the ai...

Page 11: ...TIME OF DAY If the words PRESENT TIME do not show in the display press the SELECT button until they do Press the UP or DOWN buttons to set the present time Up moves the display ahead down moves the t...

Page 12: ...l fide set the filter to recharge more often than the table above shows Press the SELECT button to set and advance to the next set up screen SET RECHARGE TIME The default setting is 12 00 AM This is a...

Page 13: ...ater flow has stoped D Make sure the ball valve on the neck adaptor is open See Figure 10 D Make sure the solenoid vent is open when the air pump is running D Make sure the vent tube is held securely...

Page 14: ...r supply to the filter use the plumbing bypass valve s feature POWER OUTAGE MEMORY If electrical power to the timer is interrupted the memory built into timer circuitry keeps all settings for several...

Page 15: ...lter through the adaptor The air oxidizes the iron The oxidized iron is then mechanically filtered by the filter mineral bed The solenoid valve allows excess air to vent from the tank SERVICE BACKWASH...

Page 16: ...16 WATER FLOW PATHS THROUGH VALVE FIGURE 11 SERVICE CYCLE FIGURE 12 BACKWASH CYCLE FLOW PLUG FIGURE 13 FAST RINSE CYCLE...

Page 17: ...ank This supplies oxygen that aerates the water and oxidizes iron manganese and hydrogen sulfide generating particles The vent solenoid is opened during this time permitting oxygen depleted air to esc...

Page 18: ...ton to move filter into fast rinse Again look for fast drain flow To return filter to service press the Touch Hold button NOTE While in manual advance the time display will automatically return to the...

Page 19: ...ay For correct filter operation the model code number must be HAIIF To reset the code press the Up or Down button until the correct number shows 3 Press Select to return the present time display If th...

Page 20: ...0 11 12 6 5 Valve Assembly see pages 22 23 1 WARNING FILTER TANK CONTAINS AIR TO RELIEVE PRES SURE PUT BYPASS VALVE IN BYPASS AND ADVANCE FILTER VALVE TO BACKWASH BEFORE DISASSEMBLY 26 15 18 17 20 14...

Page 21: ...9 Tank Base KEY NO PART NO DESCRIPTION 7112963 Distributor O ring Kit includes Key Nos 14 16 14 O ring 13 16 I D x 1 1 16 O D 15 O ring 2 7 8 I D x 3 1 4 O D 16 O ring 2 3 4 I D x 3 O D 17 7310278 Ada...

Page 22: ...PAIR PARTS 50 51 53 52 54 55 56 57 58 59 60 61 66 67 62 63 64 68 69 75 76 65 80 81 84 85 86 cross section view seal wear strip flow plug assembly assembled view 78 77 73 88 74 79 83 82 82 72 70 71 87...

Page 23: ...00 Rotor Disc 68 7171187 Plug Drain Seal 69 7129889 Spring 70 7089306 Clip 4 req KEY NO PART NO DESCRIPTION 71 7271204 Installation Adaptor 1 2 req 72 7311127 O ring 1 1 16 x 1 5 16 4 req 7290931 Turb...

Page 24: ...ECODYNE WATER CONDITIONING 1890 Woodlane Drive Woodbury MN 55125...

Reviews: