15
Programming the Water Softener
LOW SALT ALARM
Use this feature to program when the electronic control
will display a low salt alarm. The number of days can
be customized, or the feature can be turned off. The
default is 20 days.
1-3
. Go to the
Salt settings
menu by following Steps 1-
3 in “Setting Salt Level” at left.
4
. Press the DOWN (
6
) button to scroll through the
menu options until
Low salt alarm
is highlighted.
5
. Press the SELECT (
¡
) button to display the Low salt
alarm screen (See Figure 32).
Salt level
4
FIG. 31
20 days before
empty
Low salt alarm
FIG. 32
SETTING SALT LEVEL
Use this feature when adding salt to the softener.
1
. From any of the rolling status screens, press the
SELECT (
¡
) button to display the
Main menu
.
2
. Press the DOWN (
6
) button to scroll through the
menu options until
Salt settings
is highlighted (See
Figure 29).
6
. After adding and leveling salt, observe the numbered
scale on the brinewell (See Figure 31). Press UP (
5
)
or DOWN (
6
) to change the salt level to match the
lowest number visible above the salt.
7
. Press the SELECT (
¡
) button. The display will go
back to the Salt settings menu (Figure 30).
8
. Press the LEFT (
3
) button twice to return to the
rolling status screens. It will also exit automatically if
no buttons are pressed for four minutes.
3
. Press the SELECT (
¡
) button to display the Salt set-
tings menu (See Figure 30).
Recharge
Salt settings
Basic settings
Main menu
FIG. 29
Salt level
Low salt alarm
Salt settings
Salt type
FIG. 30
4
. Make sure
Salt level
is highlighted.
5
. Press the SELECT (
¡
) button to display the Salt
level screen (See Figure 31). This screen will not
automatically exit for 15 minutes.
6
. Press the UP (
5
) or DOWN (
6
) buttons to change
the number of days. Set the number of days to pro-
vide enough time to purchase salt and avoid running
into hard water. Setting the number of days below 1
turns the alarm feature off.
7
. Press the SELECT (
¡
) button. The display will go
back to the Salt settings menu.
8
. Press the LEFT (
3
) button twice to return to the
rolling status screens.
SETTING SALT TYPE
Use this feature to program the electronic control with
which type of salt is used. The default is NaCl.
Selecting KCl increases fill time 25% and brine/slow
rinse times 12%.
1-3
. Go to the
Salt settings
menu by following Steps 1-
3 in “Setting Salt Level” at left.
4
. Press the DOWN (
6
) button to scroll through the
menu options until
Salt type
is highlighted.
5
. Press the SELECT (
¡
) button to display the Salt type
menu (See Figure 33).
LEVEL
SALT
Brinewell
Numbers
Salt
Level
Sodium (NaCl)
Potassium (KCl)
Salt type
FIG. 33
6
. If the desired salt type already has a black dot next
to it (See Figure 33), go to Step 7. Otherwise, press
the softener’s DOWN (
6
) or UP (
5
) buttons to scroll
to the other salt type, then press SELECT (
¡
) to
choose it.
7
. Press the SELECT (
¡
) button. The display will go
back to the Salt settings menu.
8
. Press the LEFT (
3
) button twice to return to the
rolling status screens.