6
Refrigerant Charge
oz
38.8
50.1
Model
-
16K
22K
Throttling Method
-
Electron expansion valve
Electron expansion valve
Dimension of Outline(W)
mm
819
860
Dimension of Outline(D)
mm
309
320
Dimension of Outline(H)
mm
638
720
Dimension of Carton Box(L)
mm
972
1015
Dimension of Carton Box(W)
mm
402
445
Dimension of Carton Box(H)
mm
688
775
Dimension of Package(L)
mm
972
1015
Dimension of Package(W)
mm
402
445
Dimension of Package(H)
mm
688
775
Outdoor Unit Stacked Layers
-
4
4
Net Weight
kg
39
48
Gross Weight
kg
42
52
Outdoor Unit Loading Quantity
( 40
’
Hi h C b C
i
)
unit 192
183
Connection Pipe Connection Method
-
Flare Connection
Flare Connection
Not Additional Gas Connection Pipe Length
m
10(Liquid pipe total length)
15(Liquid pipe total length)
Connection Pipe Gas Additional Charge
g/m
12
12
Outer Diameter of Liquid Pipe(Metric)1
mm
φ
6
φ
6
Outer Diameter of Liquid Pipe(Metric)2
mm
φ
6
φ
6
Outer Diameter of Liquid Pipe(Metric)3
mm
/
φ
6
Outer Diameter of Liquid Pipe(Metric)4
mm
/
/
Outer Diameter of Liquid Pipe(Metric)5
mm
/
/
Outer Diameter of Gas Pipe(Metric)1
mm
φ
9.52
φ
9.52
Outer Diameter of Gas Pipe(Metric)2
mm
φ
9.52
φ
9.52
Outer Diameter of Gas Pipe(Metric)3
mm
/
φ
9.52
Outer Diameter of Gas Pipe(Metric)4
mm
/
/
Outer Diameter of Gas Pipe(Metric)5
mm
/
/
Connection Pipe Max. Height Distance(indoor and
indoor)
m 5
5
Connection Pipe Max. Height Distance(indoor and
outdoor and indoor up)
m 10
10
Connection Pipe Max. Height Distance(indoor and
outdoor and outdoor up)
m 10
10
Max. equivalent connection pipe length(outdoor to
last indoor)
m 25
25
Connection Pipe Max. Length Distance(total
length)
m 45
65
Low Ambient Cooling Function
-
yes yes
Defrosting Time Set Function
-
no no
Low Voltage Startup
-
yes yes
Compressor With Electric Heater
-
optional optional
Chassis With Electric Heater
-
no no
Summary of Contents for CM2-H16/4DR2
Page 1: ...Service manual FREE MATCH 50Hz R32 Models СM2 H16 4DR2 СM3 H22 4DR2 2022 06 ...
Page 3: ...1 1 Summary and Features Outdoor Unit CM2H 1644A23 CM3H 2228A23 ...
Page 11: ...9 4 Construction Views 4 1 Outdoor Unit CM2H 1644A23 Unit mm ...
Page 12: ...10 CM3H 2228A23 Unit mm ...
Page 27: ...25 8 Exploded Views and Parts List 8 1 Outdoor Unit Model CM2H 1644A23 ...
Page 29: ...27 Model CM3H 2228A23 ...
Page 47: ...41 ...