5
Model
-
16K
22K
Compressor Trademark
-
CRSS GMCC
Chassis Electrical Heater Power Input
W
/
/
Chassis Electrical Heater Current
A
/
/
Fan Type
-
Axial-flow Axial-flow
Fan Quantity
-
1 1
Fan Diameter-height
mm
455-151
496-139
Fan Diameter-height
inch
17.9-5.9
19.5-5.47
Motor Model
-
ZKFN-70-8-3 ZKFN-70-8-2
Motor Type
-
DC motor
DC motor
Motor Insulation Class
-
E E
Cooling Power Input
-
IP44 IP44
Overload Protector
-
/ /
Motor Full Load Amp(FLA)
A
0.62
0.68
Fan Motor Type
-
DC motor
DC motor
Fan Motor Drive Type
-
Direct drive
Direct drive
Fan Motor Speed
rpm
850
850
Fan Motor Power Output
W
70
70
Fan Motor Power Input
W
95
105
Fan Motor Capacitor
μ
F
/ /
Condenser Material
-
Aluminum Fin-copper Tube
Aluminum Fin-copper Tube
Condenser Face Area
m2
0.51
0.60
Condenser Face Area
sq.ft
-
-
Condenser Pipe Diameter
mm
φ
7
φ
7
Condenser Pipe Diameter
inch
0.276
0.276
Condenser Number of Rows
-
2 2
Condenser Tube Pitch(a)
×
Row Pitch(b)
mm
22
×
19.05 22
×
19.05
Condenser Fin Pitch
mm
1.4
1.4
Condenser Fins per Inch(FPI)
-
18 18
Condenser Fin Type
-
wavy fin
wavy fin
Condenser Fin Colour
-
GOLDEN GOLDEN
Condenser Number of Circuits
-
4in-4out 6in-3out
Condenser Length(L)
×
Height(H)
×
Width(W)
mm
854
×
594
×
38.1 914
×
660
×
38.1
Condenser Max. Allowable Pressure
MPa
12.6
12.6
Outdoor max operating pressure of heat
MPa 4.2
4.2
Permissible Excessive Operating Pressure for the
MPa 4.2
4.2
Permissible Excessive Operating Pressure for the
Suction Side
MPa 2.5
2.5
Maximum Allowable Pressure
MPa
4.3
4.3
High Presser Overload Protector
MPa
/
/
Low Presser Overload Protector
MPa
/
/
Cooling Operation Ambient Temperature Range
℃
-5~52
-5~52
Heating Operation Ambient Temperature Range
℃
-15
~
24 -15
~
24
Maximum drive IDU NO.
unit
2
3
Defrosting Method
-
Automatic
Defrosting Automatic Defrosting
Isolation
-
I
I
Moisture Protection
-
IP24 IP24
Overload Protector
-
/
/
Climate Type
-
T1
T1
Climate Zone
-
Temperate Zone
Temperate Zone
Refrigerant
-
R32
R32
Refrigerant Charge
kg
1.10
1.42
Summary of Contents for CM2-H16/4DR2
Page 1: ...Service manual FREE MATCH 50Hz R32 Models СM2 H16 4DR2 СM3 H22 4DR2 2022 06 ...
Page 3: ...1 1 Summary and Features Outdoor Unit CM2H 1644A23 CM3H 2228A23 ...
Page 11: ...9 4 Construction Views 4 1 Outdoor Unit CM2H 1644A23 Unit mm ...
Page 12: ...10 CM3H 2228A23 Unit mm ...
Page 27: ...25 8 Exploded Views and Parts List 8 1 Outdoor Unit Model CM2H 1644A23 ...
Page 29: ...27 Model CM3H 2228A23 ...
Page 47: ...41 ...