CONNECTION TO EXISTING EQUIPMENT
Feed and return lines
Magen eco-Spark
®
Installation manual. © 2012, all rights reserved
P a g e
|
32
CONNECTION TO EXISTING EQUIPMENT
This chapter describes the standard (and most common) method of running the pipelines from the
feed and return lines to the existing ground level equipment. Some installations may require a more
creative approach.
Whenever possible, the return line should have the shortest run and all pipes should run slightly
“downhill” to allow for automatic drain-down of the plumbing and solar array. If this is not possible,
manual drain valves must be installed as needed.
Note:
If the existing pool mechanical room is near the house, you may prefer to complete the
necessary plumbing there before connecting between the roof and ground level. That way you will
know exactly where the pipes should come down from the roof.
FEED AND RETURN LINE S
Feed and return lines are connected using a PPC connector and a Pipe Adaptor. The remaining two open
corners of the bank are sealed using PPC connectors and End Caps.
To connect the feed and return lines:
1.
Connect the feed line to the low end of the bottom header, which should be the corner
farthest from the pool pump, using a
PPC
connector and a
Pipe Adaptor
.
2.
Connect the return line to the top header on the opposite end of the bank. This gives the
heated pool water the shortest route back to the pool.
3.
Block the remaining two corners of the bank using
End Caps
attached with
PPC
connectors.
4.
Connect the feed and return pipes using reliable plumbing techniques.
Figure 9: Connecting plumbing line to the collector