Chapter II Page 3
3.
Dissolve of 30/40 grams of chemical protector (sodium metabisulfite) with the 5
liters of water you set aside in a different container and suction this solution using
the auxiliary valve (22).
4.
Close the sea cock valve (1) and start up the system by pressing PRODUCCION,
and press STOP just before the chemical protector and water solution from the
tank runs out. This way the entire circuit will contain this protecting solution.
Do not forget to keep closed the seacock valve (1) as a security measure.
5.
When the unit is ready to be turned on once again, the sea cock valve (1) must set
to open position and the valve (11) to the
TEST
position so the water produced
initially is rejected. Proceed as described in I.5 FIRST START-UP (Chapter I
Page 10).
Warning
Sodium metabisulfite is a caustic product that may cause serious irritation to the
skin and mucus membranes. Take due precautions before handling, do not touch it
directly and always work in well-ventilated spaces.