The current status is displayed.
No settings can be entered.
This display is for information only.
Pressing the button
repeatedly returns you to the start screen.
Status display symbols:
Display
Description
DHW priority active (heating circuit demand is subordinate).
Pump output active.
Minimum boiler temperature (pump release) has not been reached.
Time program active.
Burner demand via burner contact / thermostat.
Warning
12.2 Version B
Heating circuits and domestic hot water are controlled by an external controller.
The boiler controller features a "burner contact" for this purpose at terminal 7/8 (24V).
If this burner contact is closed, the burner starts.
The boiler switches to standby mode when the switch-off temperature is reached.
The boiler switch-off temperature is set at the factory to 76° C.
When the actual boiler temperature falls to 10 °C below the boiler switch-off temperature, the burner restarts.
It must be ensured that both the heating circuit pumps
and the hot water pump are only switched on when an
actual boiler temperature of 60 °C has been reached.
This prevents the formation of condensate in the com-
bustion chamber.
Note:
Non-compliance with this requirement leads to guarantee and warranty forfeiture!
200014_EN 1.2
Summary of Contents for Easypell 16
Page 1: ...Installation Manual Easypell 16 32kW ENGLISH 200014_EN 1 2 www easypell com...
Page 18: ...18 Dismantling the burner casing and burner 200014_EN 1 2...
Page 56: ...56 Retrofit motor cleaning device 200014_EN 1 2...
Page 57: ...Retrofit motor cleaning device 57 Installation Manual Easypell 16 32kW...
Page 63: ......