35
Appendix F: Setting Up ATI Vision for ECM Modules
NOTE:
While shown here for a single LambdaCAN* module, the same procedure applies for any of
ECM’s CAN-based devices (ex. NOxCAN) as well as for multiple modules simultaneously connected
on the same bus.
Introduction
Connecting ECM LambdaCAN hardware to ATI VISION software is simple and does not require any
third-party software interface. Using the ECM Configuration Tool software to produce a .dbc database
file, and the ATI VISION CANMonitor interface, any available hardware CAN interface can be used to
read LambdaCAN data.
Hardware Setup
A typical hardware configuration is shown in Figure 1. In this example, a Kvaser Leaf Light CAN-USB
adapter is used. Other supported adapters have a similar procedure. Connect the DB9 CAN connector
of the LambdaCAN to the PC to CAN adapter. Supply 11-28V DC (5A min. supply) to the
LambdaCAN.
Figure 1: Equipment Schematic Layout
PC to CAN
Adapter
Termination
Resistor
DB9 Connector
CAN
Software
ATI VISION 3.6.2
ECM Configuration Tool v4.13
PC with
ATI VISION
and ECM
Configuration
Tool
USB
Kvaser Leaf Light
LambdaCAN
DC Power Supply
11-28V
Summary of Contents for LambdaCAN Series
Page 48: ...44...
Page 49: ......