15
Here is an example of setting analog output 2 for a (i.e. A2):
1.
Press the SYS key so that “MOd” appears on the top display.
2.
Press the
key until “AOUT” is on the top display. Then press the ENT key.
3.
Press the
key until “A2” (analog output 2) is on the display. Then press the ENT
key.
4.
Press the
and
key until the parameter (see Table 2) that will drive A2 is displayed.
Then press the ENT key.
5.
When 0V is displayed, press ENT. Using the
,
, and ENT keys, set the parameter
value that you want to result in an analog output voltage of 0V on analog output 2.
The first time you do this, it may be a little tricky. You are setting one digit at a time
and for some numbers, the display will shift to the left so you can set the right-most
digits. If you get into trouble when programming, press the SYS key twice to exit and
re-enter setup to try again.
6.
When 5V is displayed, press ENT. Using the
,
, and ENT keys, set the parameter
value that you want to result in an analog output voltage of 5V on analog output 2.
7.
When “AOUT” is displayed, press SYS to return to RUN mode.
If in the above example analog output 4 was being programmed, AOUT, A4, 0V, 5V, and
your entries would be shown on the bottom display.
dISP (Display) Setup Option
The dashCAN* display head has two displays, the top display and the bottom display.
In dISP setup, a parameter from the module assigned to the display (see MOd) can be shown
on the display. Only parameters selected as active TBDOs for that module (using the
Configuration Tool) can be displayed.
Here is an example of setting the parameter to be displayed on the top display:
1.
Press the SYS key so that “MOd” is displayed.
2.
Press the
key until “dISP” is on the top display. Then press the ENT key.
3.
Press the
and
key until desired parameter name is displayed. See Table 2. Then
press the ENT key.
4.
Press SYS to return to RUN mode.
CONF (Configure) Setup Option
CONF setup appears at the end of the setup list on the bottom display. To enter CONF, press
the SYS key so that “MOd” appears on the top display, press the
key until “CONF” appears
on the bottom display, and then press the ENT key. CONF is for global dashCAN* setup.
LEdS ( only)
The display intensity is programmable. Press the ENT key when “LEdS” appears on the
bottom display, press the
or
keys until the display intensity is suitable, press ENT, and
press SYS to return to RUN mode.