1
Introduction
ECM offers three Lambda module kits: LambdaCANp, LambdaCANd, and LambdaCAN.
LambdaCANp is the latest Lambda module kit and can optionally be supplied with a P-comp
(pressure compensation) kit. The P-comp kit for LambdaCANp uses a pressure sensor with
an eight terminal connector. This eight terminal connector contains a memory chip with the
calibration of the pressure sensor (i.e. “plug-and-play”). LambdaCAN is the original kit
released and can also optionally be supplied with a P-comp kit. A LambdaCANd kit is
simply a LambdaCAN kit with the P-comp kit supplied as standard equipment. Both the
LambdaCAN and LambdaCANd kits use a pressure sensor with a four terminal connector.
The calibration numbers for this pressure sensor are written on a label attached to the sensor
harness and must be entered into the LambdaCAN or LambdaCANd before use (this is done
by ECM when a P-comp kit is delivered with the LambdaCAN or LambdaCANd). See
Appendix A for kit contents. The specifications for the kits are as follows:
LambdaCANp Kit:
Ranges:
λ (Lambda):
0.4 to 25
AFR:
6 to 364
F/A:
0.003 to 0.167
Φ:
0.04 to 2.5
%O2:
0 to 25% (wet)
P (pressure, optional)
: 0 to 517 kPa (0 to 75 psia)
Accuracies:
λ, AFR, F/A, Φ:
± 0.6% (at stoichiometric), ± 0.9 (average, elsewhere)
%O2:
± 0.1% (absolute)
P:
± 0.7 kPa, (± 0.10 psia)
Response Times:
λ, AFR, F/A, Φ, O2:
Less than 150 ms
Sensor Mounting: 18mm x 1.5mm thread
LambdaCAN and LambdaCANd Kits:
Ranges:
λ:
0.4 to 25
AFR:
6 to 364
F/A:
0.003 to 0.167
Φ:
0.04 to 2.5
%O2:
0 to 25% (wet)
P (pressure, optional for LambdaCAN)
: 0 to 517 kPa (0 to 75 psia)
Accuracies:
λ, AFR, F/A, Φ:
± 0.6% (at stoichiometric), ± 0.9 (average, elsewhere)
%O2:
± 0.1% (absolute)
P:
± 5.2 kPa, (± 0.75 psia)
Response Times:
λ, AFR, F/A, Φ, O2:
Less than 150 ms
Sensor Mounting: 18mm x 1.5mm thread