218
Figure 5-65
Please refer to the following sheet for detailed information.
Parameter Function
Event
Type
The abnormal events include: No disk, disk error, disk no space, net
disconnection, IP conflict and MAC conflict.
You can set one or more items here.
Less than: You can set the minimum percentage value here (For disk
not space only). The device can alarm when capacity is not sufficient.
You need to draw a circle to enable this function.
Enable
Check the box here to enable selected function.
Alarm Out
Please select corresponding alarm output channel when an alarm
occurs. You need to check the box to enable this function.
Latch
The alarm output can delay for the specified time after an alarm stops.
The value ranges from 1s to 300s.
Show
message
System can pop up a message to alarm you in the local host screen if
you enabled this function.
Alarm
upload
System can upload the alarm signal to the centre (Including alarm
centre.
Send
Email
If you enabled this function, System can send out an email to alert you
when an alarm occurs.
Buzzer
Check the box here to enable this function. The buzzer beeps when an
alarm occurs.
5.8.3.5 Alarm Output
It is to set alarm output mode. See Figure 5-66.
Summary of Contents for ECL-HYDVR32B
Page 1: ...ECL HYDVR32B DVR User s Manual V1 3 0 Our units do not support PAL ...
Page 22: ...40 ...
Page 107: ...128 Figure 4 90 Figure 4 91 ...
Page 108: ...129 Figure 4 92 Figure 4 93 ...
Page 114: ...135 Figure 4 98 Figure 4 99 ...
Page 115: ...136 Figure 4 100 Figure 4 101 ...
Page 118: ...139 Figure 4 105 Figure 4 106 ...
Page 131: ...152 Figure 4 125 Figure 4 126 ...
Page 199: ...220 Figure 5 68 Figure 5 69 Please refer to the following sheet for detailed information ...
Page 253: ...274 ...