![Eclipse EC-P8 Installation Manual Download Page 27](http://html1.mh-extra.com/html/eclipse/ec-p8/ec-p8_installation-manual_4021851027.webp)
P0031-LI-02.01
27
5. Expander Configuration
This section covers programming of the expander module. The EC-
P8 will only accept one expander module (EC-EX10 or EC-EX10/I).
The expander MUST be set to address 1.
Expander Options
This set of options controls how the expander tamper and internal
piezo sounder function.
Location:
5111
Entry Mode:
Bit Toggle Selection (see page 16).
1 Enable
Tamper
On: The lid tamper on the expander is monitored.
Off: The lid tamper on the expander is not monitored.
2 Enable
Piezo
On: The internal piezo sounder on the EC-EX10 expander is
enabled.
Off: The internal piezo sounder on the EC-EX10 expander is
disabled.
Expander Sounds
This set of options controls how the EC-EX10 expander generates
sounds from its on-board piezo sounder and loudspeaker output.
Location:
5121
Entry Mode:
Bit Toggle Selection (see page 16).
1 Alarm
Tones
On: The expander generates alarm tones.
Off: The expander will not generate alarm tones.
2 Trouble
Tones
On: The expander generates trouble tones.
Off: The expander will not generate trouble tones.
3 Chime
Tones
On: The expander generates chime tones.
Off: The expander will not generate chime tones.
4 Entry
Tones
On: The expander generates entry tones.
Off: The expander will not generate entry tones.
5 Exit
Tones
On: The expander generates exit tones.
Off: The expander will not generate exit tones.
6
Key Press Tones
On: Not supported on the expander.
Off: Not supported on the expander.
7 Advisory
Tones
On: The expander generates advisory tones.
Off: The expander will not generate advisory tones.
8 Tamper
Tones
On: The expander generates tamper alarm tones.
Off: The expander will not generate tamper alarm tones.
Expander Outputs
The EC-EX10 has 10 programmable outputs. This set of options
allows the output type (function) to be assigned to each of the
expander outputs.
Locations:
5201
to
5210
Expander 1: Output 1 to 10 Type.
Entry Mode:
Selection List (see page 15).
Enter the four digit type number, e.g., 0301 = “Zone 01 Alarm”.
See page 28 for a complete list of output functions.
Expander Output Attributes
This set of options allows the output attributes to be assigned to
each of the expander outputs.
Locations:
5301
to
5310
Expander 1: Output 1 to 10 attributes.
Entry Mode:
Bit Toggle Selection (see page 16).
See page 28 for details on output attributes.
Summary of Contents for EC-P8