String Edit - Text Mode
This type of data entry is used for entering text such as user
names and zone text. This mode is designed only for the LCD
keypad. The text is entered in the same way as entering text on a
mobile telephone. Each key is mapped to one or more letters.
Pressing a key will select the first letter, pressing it again will
select the next etc. The table below shows the keys to use and the
characters that are assigned to them:
Key Characters
1
1
2
A B C 2 a b c
3
D E F 3 d e F
4
G H I 4 g h i
5
J K L 5 j k l
6
M N O 6 m n o
7
P Q R S 7 p q r s
8
T U V 8 t u v
9
W X Y Z 9 w x y z
0
_ 0 . - ( ) #
B
Clear all characters
The figures below show the programming procedure for LCD
remote keypads:
String Edit - Text Mode: LCD Keypad
Engineers Menu
Location:----
Engineers Menu
Location:1801
Zone 01 Text
ÿ
Enter Engineers code
????
Enter location No
e.g. 1801
????
Press
to display
the current value
*
Press
to accept
and return to step
*
Ì
Press
to cancel
and return to step
R
Ê
Press
to accept
and move to next location.
#
Zone 01 Text
HALLÿ
Use text editing keys
to enter text, e.g, HALL
Location number & current
value are displayed (blank).
1. Zone Programming
This section covers programming of the detection zones, each
zone must programmed a zone type, wiring type and attributes.
Zone Type
Each zone must be programmed to the correct type in order for
the correct response.
Locations:
1101
to
1118
Zone 01 to 18: Zone Type.
Entry Mode:
Mode: Selection List (see page 15).
00 Not
Used
Use this zone type for unused zones, as zone programmed as
“Not Used” are not be monitored by the system.
01 Delay 1/Final Exit 1
Use this zone type for the main entry/exit detector, normally a
magnetic contact on the front door. The zone can be activated
during the exit mode without causing a fault. If the system is
armed, activation of the zone will start the Entry 1 Delay timer for
the relevant arm mode.
02 Delay 2/Final Exit 2
Use this zone type for an alternative entry/exit detector. The zone
can be activated during the exit mode without causing a fault. If
the system is armed, activation of the zone will start the Entry 2
Delay timer for the relevant arm mode.
03 Follower/Entry
Route
Use this zone type for detection devices along the entry/exit
route. This zone type will allow the user to walk past the detector
without causing a fault during the exit mode or an Intruder alarm
during the entry mode. However, if activated at any other time the
zone will cause an immediate intruder alarm. This zone type will
also start the entry mode when the system is stay armed.
04 Intruder
Use this zone type for detection devices such as PIR’s, vibration
detectors, magnetic door contacts etc. This zone type generates
an intruder alarm if activated when the system is armed.
05 Perimeter
Use this zone type for detection devices such as external PIR’s, IR
beams. This zone type generates an intruder alarm if activated
when the system is armed.
06 Fire
Use this zone type for smoke and heat detectors. This zone type
generates a distinctive fire alarm if activated at any time.
07 PA
Silent
Use this zone type for panic buttons. This zone type generates a
silent panic alarm if it is activated at any time.
08 PA
Audible
Use this zone type for panic buttons. This zone type generates an
audible panic alarm if it is activated at any time.
09 Medical
Use this zone type for medical alarms. This zone type generates a
medical alarm if it is activated at any time.
10 24
Hour
Use this zone type for detectors that require 24 hour monitoring.
This zone type generates an intruder alarm if it is activated when
the system is armed. If activated during the disarmed state an
internal alarm is generated.
11 Tamper
Use this zone type for tamper protection. This zone type generates
a tamper alarm if it is activated when the system is armed. If
Summary of Contents for EC-P8
Page 1: ...EC P8 8 18 Zone Intruder Alarm System Installation Manual...
Page 4: ...4 P0031 LI 02 01 1 System Overview System Configuration...
Page 45: ...P0031 LI 02 01 45 Notes...
Page 46: ...46 P0031 LI 02 01 Notes...
Page 47: ...P0031 LI 02 01 47 Notes...
Page 48: ...Technical Support Email support zetaalarmsystems com...