LED Status
This section describes the status of operating conditions based on the LED or combination of LEDs which are lit on the
front cover of each Veri-Flame model.
LED Status and Conditions for Veri-Flame No Purge Models
LED(s) Lit
Possible Cause
Interlocks Closed
The interlocks are closed (normal operation), power on terminal 7.
System Error
1. The flame detected is out of sequence, flame signal light is on.
2. The sensor is “runaway,” flame signal light is on.
3. Inductance is detected on sensor wires, flame signal light is on.
4. Voltage wired into terminals 3, 4, or 5.
5. Internal relay contacts welded.
6. Internal controller failure.
7. Main valve closed switch defective, no power to V.
Flame Failure
1. Pilot flame is not established in selected TFI.
2. Main flame is not established in selected TFI.
3. Main flame fails within 35 seconds of TFI.
4. Flame failed during operation in non-recycle mode.
5. Flame failed 35 seconds after TFI and was not established after try in recycle mode.