Figure 3.3
Vortometric Burner Mounting Arrangements
3-13
Provide adequate
shell stiffeners
Furnace backstay
Weld heads of mounting bolts inside furnace shell plate.
Allow for 3mm (1/8") thick, high temperature gasket
between the burner flange and shell plate.
Furnace shell plate
229mm (9")*
Flange position on standard burner allows correct shell dimension above
*178mm (7") for 6V and 8V medium intensity burner sizes.
To allow for thermal expansion of combustion liner extension,
the main wall should be constructed with an opening 25mm (1") greater
in diameter than diameter of combustion liner.
The outside of combustion liner should be covered with 1/8" thick
insulating paper. The remaining gap between the burner and main wall
should be densely packed with ceramic fiber or wool blanket insulation.
3mm (1/8") high temp. gasket
(Customer supplied)
Ring
90 hold
Smooth refractory
flush with throat
Main flame
scanner
152mm (6")
minimum
for standard
burner mounting
76mm (3")
maximum
projection
Burner mounting
box by customer
229mm to 457mm
(9" to 18")
229mm (9") minimum
Cup angle or special anchor
fitting welded to shell plate
1
2
3
4
5
6
7
Furnace Backstay
Furnace Shell Plate
Block Insulation
Insulated Fire Brick
Fire Brick
Castable Refractory Ring (Alternate Plastic)
Refractory or Alloy Anchor
(305mm to 457mm or 12" to 18" apart)
5
6
7
4
3
1
2
Alternate Mounting Arrangement
For Thin Walls
Alternate Mounting Arrangement
For Thick Walls
Suggested Mounting Arrangement
For Standard Burner
General Notes:
1. Mounting illustrations show typical Vortometric combustor blocks of high alumina
plastic refractory as used by Eclipse for normal duty.
2. The dimensions given must be held as specified, and the inner diameter of the
combustor must be round and concentric with the throat cone.
3. Alloy rod-type anchors welded inside the combustor block are the customer’s
responsibility if the refractory is field installed rather than factory installed.
4. All mounting arrangements are meant for vertically or horizontally fired burners.
Regardless of orientation, the refractory block MUST be protected from thermal
expansion of the furnace wall.
30
Eclipse Vortometric Burner v2.00, Installation Guide 248, 4/10/07