B-FOCuS O-4F2PW/O-4G2PW Hardware Installation Manual
02-Oct-2011
ECI Telecom Ltd. Proprietary
10
Rev 0.1
5.
Slide the ONT unit into the mounting bracket in up to down direction, using the 4 guides on the
bracket. Make sure the panel with the interfaces is facing down in case of horizontal mounting, or
facing left in case vertical mounting.
6.
Remove the dust covers from the SC/APC optical connectors. Clean the connector if necessary.
7.
Plug in the fiber connector to connect the ONT to the network.
3.3.2
Install the ONT on Desktop
1.
Locate a safe and accessible site for installation.
2.
Place the ONT unit on the desk.
3.
Remove the dust covers from the SC/APC optical connector. Clean the connectors if necessary.
4.
Plug in the fiber connector to connect the ONT to the network.
3.3.3
Uninstall the ONT
For uninstall the ONT on the wall:
1.
Plug out the SC/APC optical connector.
2.
If necessary, slide the ONT unit out of the mounting bracket in down to up direction.
3.
If necessary, remove the optical fiber cables.
4.
If necessary, remove the bracket mounting screws and then remove the mounting bracket.
For uninstall the ONT on the desktop:
1.
Plug out the SC/APC optical connector.
2.
If necessary, remove the optical fiber cables.
3.4
Connecting Power
1.
Plug the circle two pin 12V DC power connector of power converter to ONT power port
2.
Plug the input of power converter into a live AC outlet
3.
Verify that the power (PWR) LED on the ONT is lit green indicating that local power is on and
voltage is good.
3.5
Connecting Telephone (POTS) Service
1.
Locate the premises’ telephone wire pair.
2.
If the wire pair is not terminated, follow local practices to attach an RJ-11 connector..
3.
Plug the wire pair with RJ-11 connector into one of the ONT RJ-11 phone jacks.
4.
Repeat step 2-3 as needed to connect additional phone lines.