Echoflex Installation Guide
Elaho Preset Station
Installation
Installation should follow all local codes and standard electrical practices.
The back box should be installed level and square for best results. Ensure
that the back box is clean and free of obstructions.
Note:
NEC Class 2 product to be wired in accordance to NEC
Article 725 and local jurisdiction requirements.
Note:
When using Category 5 (or equivalent) cable on the
EchoConnect communication bus, please note the following:
• Cat5 wiring must be terminated using EchoConnect Cat5
Termination Kits and must be installed using a bus topology.
Refer to the instructions provided with the Cat5 Termination
Kit (8186A1207) for information to terminate Cat5 wiring.
• Not all topologies are supported using Cat5; careful
planning is required to ensure the proper termination kits
are available and the wire is pulled appropriately.
Connect Wiring
1. Pull all required wiring (data+, data–) and an additional 2.5 mm
2
(14 AWG) ESD ground wire into the back box.
Note:
A ground connection is required between every station
and back box, even when installed with grounded metal conduit.
2. Connect station ESD ground wire pigtail.
a. Strip 11 mm (7/16 in) of insulation from the ends of the station
ground wire pigtail provided in the termination kit and from the
incoming ground wire.
b. Use one WAGO 221 Series LEVER-NUTS
®
provided in the
termination kit to connect the station ESD ground pigtail and
the incoming ground. For stations using grounded metal
conduit, connect the ground pigtail to the metal back box
ground location.
c. Install the ESD ground wire pigtail FASTON connector to the
mating receptacle on the station electronics.
Elaho Preset Station
Page 4 of 8