SPECIFICATIONS
Natural Gas (NG)
Propane (LP)
Manifold Pressure
1.7 - 3.5 in. w.c.
3.8 - 10.0 in. w.c.
Min. Supply Pressure for
Purpose of Input
Adjustment
5.00 in. w.c. (1.2 kPa)
11.5 in. w.c.
Max. Supply Pressure for
Purpose of Input
Adjustment
7.0 in. w.c.
13.0 in. w.c.
Orifice Size
35# DMS
53# DMS
Nominal Input Rating
31,000 BTU/hr
26,000 BTU/hr
Altitude
0 - 2000ft. (0 - 610 m) US
0 - 4000ft. (0 - 1219 m) Canada
0 - 2000ft. (0 - 610 m) US
0 - 4500ft. (0 - 1371 m) Canada
Primary Air Opening
1/8in (Minimum)
1/8in (Minimum)
Vent System
Co - axial (4” x 7”)
Co - axial (4” x 7”)
Log Set
Ceramic (6 Piece)
Ceramic (6 Piece)