INSTALLATION
Clearance to Combustibles
Due to high temperatures, the room heater should
be located out of traffic and away from furniture
and draperies. Children and adults should be alerted
to the hazards of high surface temperature and
should stay away to avoid burns or clothing
ignition.
Floor Protection
When the appliance is installed directly on
carpeting, tile or other combustible material other
than wood flooring, the appliance shall be installed
on a metal or wood panel extending the full width
and depth of the. In addition, the following criteria
must be adhered to when installed:
1.
Install on level and secure floor.
2.
Due to high temperatures, the room heater
should be located out of traffic and away from
furniture and draperies.
3.
When placed in a location where the floor-to-
ceiling height is under 7’, the installation is
considered an alcove and must meet the
following criteria: Floor to ceiling of alcove
must be a minimum of 45”. The depth of the
alcove must be at least 27”.
Bedroom Installation
This Direct Vent appliance may be installed in a
sleeping room provided the wall thermostat option
is utilized.
FIGURE 2 – CLEARANCE TO
COMBUSTIBLES
Finishing Materials – Definition
Combustible
materials:
Such
as
wood,
compressed paper, plant fibers, plastics or any
material capable of igniting and burning, whether
flame proofed or not, plaster or un-plastered.
Non-combustible material:
Material such as steel,
iron brick, tile, concrete or materials that that bear
the UL mark for zero (0) fire rating.
VENTING
IMPORTANT:
This appliances venting system is
room sealed, which means that there should be no
provision to allow room air to be used in the
combustion process
.
NOTE:
Venting systems listed below may be used
with the model Echo: Simpson Duravent DV,
Metalbestos DV, Excel DV, Security DV.
5” back wall
7” side wall
Clearance to combustibles (see label)
Side wall
7”
Back wall
5”
Floor
0”
Ceiling height
5ft (from floor)
WARNING!
Do not cover the grills on this appliance in any way as
this may create a fire hazard.
Summary of Contents for DIRECT VENT GAS HEATER
Page 9: ...ECHO DIRECT VENT GAS HEATER 9 LABORATORY LISTING LABEL...
Page 10: ...ECHO DIRECT VENT GAS HEATER 10 FIGURE 1 DIAGRAM OF DIMENSIONS...
Page 14: ...ECHO DIRECT VENT GAS HEATER 14 FIGURE 3 VENT TERMINATION LOCATIONS...
Page 17: ...ECHO DIRECT VENT GAS HEATER 17 FIGURE 6 DIAGRAM OF VENTING REQUIREMENTS...
Page 22: ...ECHO DIRECT VENT GAS HEATER 22 FIGURE 14 VENTING REQUIREMENTS...
Page 23: ...ECHO DIRECT VENT GAS HEATER 23 FIGURE 15 VENTING CHART 18...
Page 28: ...ECHO DIRECT VENT GAS HEATER 28 FIGURE 20 LOCATION OF PILOT BURNERS AND AIR SHUTTER...
Page 30: ...ECHO DIRECT VENT GAS HEATER 30 FIGURE 21 DIAGRAM OF CONTROL COMPONENTS...
Page 31: ...ECHO DIRECT VENT GAS HEATER 31 FIGURE 22 AIR RESTRICTOR See Figure 25 and Figure 26...
Page 32: ...ECHO DIRECT VENT GAS HEATER 32 FIGURE 23 GAS VALVE AND PILOT ASSEMBLY...
Page 45: ...ECHO DIRECT VENT GAS HEATER...