ECHO
DIRECT VENT GAS HEATER
29
INSTALLATION CHECKLIST
Check off the following list before proceeding to light the heater.
There are no combustibles placed within 36” of heater or vent pipe or any combustibles that can swing
within 36” of heater such as door drapes, etc.
The location of the main shut off valve is known by everyone in the house (it is usually next to the gas
meter or propane tank). EVERYONE must know where this valve is located.
All necessary permits and installation information have been obtained and the final inspection has been
performed by the local building inspector.
The operation instructions located on the gas valve panel door have been read and understood. A copy of
these instructions can be found in the “Operations” section of this manual.
The operator and pilot igniter have read this manual thoroughly and understand it.
Burner and Pilot Checks
A periodic check of the pilot and burner flames
should be made. Check after the fire has been on for
at least 30 minutes. The pilot flame must cover the
tip of the thermocouple and thermopile probes, if
the pilot flame does not sufficiently cover the
probes it can be adjusted using the pilot adjustment
screw found on the front of the gas valve. The main
burner flame pattern will vary from appliance to
appliance depending on the type of installation and
climatic conditions.
OPERATION
Location of Controls
See Figure 21 for location of controls. Control
functions are outlined below.
Gas Control Knob
This knob is used for starting the pilot and has three
(3) positions: On, Off, and Pilot. The pointer
directly above the knob indicates the position the
knob is in.
Hi/Lo Flame Adjust
This knob controls the burn, either high or low. It is
operated manually by turning the knob. Once in
position, the wall thermostat will turn on the burner
to the position which this knob is set.
Pilot Igniter
This button is used to ignite the pilot. It is pushed
in while the gas control knob is in the Pilot
position. When pressed, it creates a spark at the
pilot, igniting it.
Burner On/Off Switch
This switch turns the burner on after the pilot is lit.
When the wall thermostat is hooked up, this switch
will remain in the “On” position after the pilot is lit.
The wall thermostat will then turn the heater on
automatically when indicated.
Summary of Contents for DIRECT VENT GAS HEATER
Page 9: ...ECHO DIRECT VENT GAS HEATER 9 LABORATORY LISTING LABEL...
Page 10: ...ECHO DIRECT VENT GAS HEATER 10 FIGURE 1 DIAGRAM OF DIMENSIONS...
Page 14: ...ECHO DIRECT VENT GAS HEATER 14 FIGURE 3 VENT TERMINATION LOCATIONS...
Page 17: ...ECHO DIRECT VENT GAS HEATER 17 FIGURE 6 DIAGRAM OF VENTING REQUIREMENTS...
Page 22: ...ECHO DIRECT VENT GAS HEATER 22 FIGURE 14 VENTING REQUIREMENTS...
Page 23: ...ECHO DIRECT VENT GAS HEATER 23 FIGURE 15 VENTING CHART 18...
Page 28: ...ECHO DIRECT VENT GAS HEATER 28 FIGURE 20 LOCATION OF PILOT BURNERS AND AIR SHUTTER...
Page 30: ...ECHO DIRECT VENT GAS HEATER 30 FIGURE 21 DIAGRAM OF CONTROL COMPONENTS...
Page 31: ...ECHO DIRECT VENT GAS HEATER 31 FIGURE 22 AIR RESTRICTOR See Figure 25 and Figure 26...
Page 32: ...ECHO DIRECT VENT GAS HEATER 32 FIGURE 23 GAS VALVE AND PILOT ASSEMBLY...
Page 45: ...ECHO DIRECT VENT GAS HEATER...