background image

Support: 

Support.Eccotemp.com                

Shop Online:

 Eccotemp.com             

Store Locator:

 Eccotemp.com/locator

20

ENGLISH

PLEASE NOTE: MINI TANKS ARE FOR INDOOR PERMANENT INSTALLATIONS ONLY. 

BEFORE POWERING THE WATER HEATER, BE SURE THAT THE SYSTEM IS COMPLETELY FILLED WITH WATER 

AND ALL AIR IS REMOVED.

THIS MANUAL AND ALL ECCOTEMP CONTENT IS SUBJECT TO CHANGE WITHOUT NOTICE. PLEASE VISIT SUPPORT.ECCOTEMP.COM FOR MORE INFORMATION.

MAINTENANCE

HOUSEKEEPING

When properly maintained, your water heater will provide years of dependable 

trouble-free service. It is recommended that a periodic inspection of the pipe 

connections be done every 6 months. 

At least once a year, lift and release the lever handle on the pressure relief valve. 

It is located between the hot and cold water lines and make certain the valve 

operates freely. Allow several gallons to flush through the discharge line to an 

open drain.
Inspect the area around the water heater to ensure a safe operating 

environment. Keep the water heater area clear and free from any objects that 

could damage the water heater. If damage or denting is present, contact a 

service personnel to verify proper operation.

DO NOT

 operate the water heater if you feel something is wrong.

DO NOT

 allow children to operate or otherwise handle the water heater.

NOTICE! If the pressure relief valve on the hot water heater discharges 

periodically, this may be due to a problem in the water system. Contact 

the water supplier or your plumbing contractor on how to correct this. DO 

NOT plug the relief valve outlet.

Maintenance

DRAINING AND STORAGE

Draining your water heater:

1. Unplug the water heater.

2. Open a hot water faucet to let hot water run out. Allow water to flow until    

    water is no longer hot.

3. Turn off the cold water supply to the water heater.

4. Close the hot water faucet.

5. Disconnect the water heater from both the hot and cold water connections.
6. If possible, siphon out any remaining water.
7. Carefully detach the water heater from the wall (if applicable).
8. Tilt the water heater to drain remaining water out of the heater.

NOTICE! When not being used for a lengthy period of time, you can 

conserve energy by reducing the temperature setting either manually or 

through the Eccotemp App. 

Protect against freeze damage if you plan on not using the water heater for an 

extended period of time. Unplug your water heater and drain. 

Summary of Contents for SMARTHOME ESH-2.5

Page 1: ...E MANUAL SMARTHOME Mini Tank Water Heater HEATING WATER SMARTER PHONE 1 866 356 1992 EMAIL SUPPORT ECCOTEMP COM ADDRESS 315 A INDUSTRIAL ROAD SUMMERVILLE SC 29483 THE FUTURE OF EFFICIENCY ESH 2 5 4 0...

Page 2: ...0 psi MODEL le mod le RATED POWER Puissance nominale RATED VOLTAGE Tension Nominale TANK CAPACITY Capacit du r servoir ESH 4 0 MAX RATED PRESSURE Pression Maximale Nominale Conforms To UL STD 174 Cert...

Page 3: ...an a combination temperature and pressure relief valve certified as meeting the requirements for relief valves ANSI 21 22 by a nationally recognized testing laboratory that maintains periodic inspecti...

Page 4: ...helpdesk located at support eccotemp com READ THE SAFETY INFORMATION Your safety and the safety of others are very important There are many important safety messages in this manual and on your water...

Page 5: ...ore Hydrogen gas is extremely flammable To reduce the risk of injury under these conditions it is recommended that the hot water faucet be opened for several minutes at the nearest and most distant si...

Page 6: ...h included hardware or they can be placed freestanding Eccotemp SMARTHOME Mini Tank models are designed to operate at 150 psi maximum water pressure Install a pressure reducing valve if your water pre...

Page 7: ...sel water tank is welded glass lined steel and is equipped with an anode rod Water is supplied by standard 1 2 Inch NPT connections The water heater is equipped with a thermostat and a high limit temp...

Page 8: ...SE VISIT SUPPORT ECCOTEMP COM FOR MORE INFORMATION Wiring Diagram Electrical Pressure and Recovery Specifications Technical Specifications y a l e R Transformer ACL2 OUT ACL1 ACN1 ACN2 WiFi Board Ther...

Page 9: ...r will not be liable for any damages because of failure to comply with these installation instructions or because of improper installation performed by an unqualified installer Wall Mounted Fasten the...

Page 10: ...ur tank and void your warranty In order to protect the water heater from heat damage due to soldering solder a piece of tubing to a threaded union fitting before screwing the union to the tank 1 Insta...

Page 11: ...on the cold water supply line The expansion tank must have a minimum capacity of 1 5 U S gallons for every 50 gallons of stored water 2 Install a 125 PSI pressure relief valve in the cold water supply...

Page 12: ...t water 4 Must not be over 15 inches in length 5 Must not have more than two elbows 6 Must terminate at an adequate drain 7 Must not have a shut off valve between relief valve and tank or relief valve...

Page 13: ...ith water and ALL AIR IS REMOVED To be certain that all of the air is out of the water heater open the HOT water faucet on the fixtures until constant water flows from them If air remains in the tank...

Page 14: ...G STARTED Connect your Water Heater to your Smart Devices The Eccotemp SMARTHOME Mini Tank Water Heater has an easy to use mobile app that will allow you to control functions such as ON OFF and temper...

Page 15: ...WITHOUT NOTICE PLEASE VISIT SUPPORT ECCOTEMP COM FOR MORE INFORMATION GETTING STARTED Have a problem with your Eccotemp ESH Our SMARTHOME app can tell you exactly what the problem is Download it toda...

Page 16: ...ord Temperature Dial Right Rear of Water Heater Manual Mode Turn the dial in either direction to adjust your temperature up or down Turn clockwise to increase temperature and turn counterclockwise to...

Page 17: ...R MORE INFORMATION USING THE APP 1 Dowload the App to get Started Find and download the Eccotemp smart phone app on the Apple App Store or the Google Play Store by typing Eccotemp into the search pane...

Page 18: ...consumption Regularly using and reviewing the app will help you fine tune your water heating needs while helping you use less resources to do so ultimately saving you money 4 Getting Connected Connec...

Page 19: ...adding a new device Once added to either app you will then be able to use voice commands Note All commands begin with Alexa or Ok Google before issuing a command to the respective device Note This ch...

Page 20: ...ng is present contact a service personnel to verify proper operation DO NOT operate the water heater if you feel something is wrong DO NOT allow children to operate or otherwise handle the water heate...

Page 21: ...ENT INSTALLATIONS ONLY BEFORE POWERING THE WATER HEATER BE SURE THAT THE SYSTEM IS COMPLETELY FILLED WITH WATER AND ALL AIR IS REMOVED THIS MANUAL AND ALL ECCOTEMP CONTENT IS SUBJECT TO CHANGE WITHOUT...

Page 22: ...R PERMANENT INSTALLATIONS ONLY BEFORE POWERING THE WATER HEATER BE SURE THAT THE SYSTEM IS COMPLETELY FILLED WITH WATER AND ALL AIR IS REMOVED THIS MANUAL AND ALL ECCOTEMP CONTENT IS SUBJECT TO CHANGE...

Page 23: ...opening the hot water tap there should be no water flowing Any continuous flow indicates a cross over which will effect the temperature and will need to be corrected If you are unable to determine a p...

Page 24: ...ni reports an E2 Error the power button will blink blue twice 2 times and then pause for three 3 seconds before repeating until the issue is fixed A rapid temperature increase is typically caused by t...

Page 25: ...ed in a hot water circulation loop in series with a circulation system or where an on demand recirculation system is not incorporated The EM Mini Tank series is approved for commercial use Eccotemp wi...

Page 26: ...his Warranty In order to make a claim under this Warranty The Owner must notify Eccotemp of the failure of the Product to conform to this Warranty Under this Warranty Eccotemp Systems will only provid...

Page 27: ...eating Capacity Max Operating Pressure Fittings Warranty Suggested Uses 2 5 Gallon and 4 Gallon Models 110 120 12 Single 50 140 F 1400 Watts 150 psi 1 2 NPT Connections SmartHome Mobile App Outer Case...

Reviews: