17
(4) Check the coating machine and hose joints for paint leakage. Set the operating pressure to between
2MPa and 16MPa.
The maximum operating paint pressure for this gun is 21MPa. Never use it with a
paint pressure exceeding 21MPa. Doing so may damage the gun or lead to injury
or other accidents from the ejected paint.
(5) Lock the trigger again and install the air wrap airless electrostatic spray nozzle.
There is a possibility of injury.
When spraying is not performed, always raise the slider at the trigger to lock
the trigger.
(6) Set the wrap air pressure regulator to between 0.1MPa and 0.5MPa.
Air comes out of the nozzle as the gun is triggered. In order to adjust the spray pattern, rotate the air
flow control knob counterclockwise to increase the air flow and decrease the spray pattern width or
rotate it fully clockwise to decrease the air flow to zero and increase the spray pattern width.
Note that the spray pattern width cannot be varied enough at a higher paint pressure.
(7) Turn on the power switch on the controller and check that the green lamp is on.
(8) Incline the slider inside the trigger downward and trigger the gun. If the red lamp on the controller lights,
this means that a high voltage has been applied to the tip of the gun. The output voltage can be
adjusted.
(9) Start coating operation.
Discharges from the air wrap airless electrostatic spray gun may cause electric
shock or fire. In steps 3 to 9, always hold the gun grip with the one hand and
operate the machine with the other hand.
③
Termination of operation
(1) If you want to interrupt operation or restart within 24 hours:
1. Be sure to turn off the power switch on the controller.
2. Reduce the operating pressure of the paint pump to 0MPa.
(Rotate the air pressure regulator counterclockwise to zero.)
3. Trigger the gun to remove the paint in the pressurized paint circuit to reduce the pressure to zero.
4. Thoroughly wipe off the paint mist and other contaminants deposited to the nozzle and barrel by
means of a cloth soaked with solvent. Remove the nozzle and remove the paint deposited to the gun
and nozzle seats.
5. Reduce the wrap air pressure and slightly trigger the gun to release the wrap air only and remove the
solvent that has intruded into the air circuit.
6. Reduce the wrap air pressure to 0MPa again.
7. Lock the trigger to terminate operation.
WARNING
WARNING
WARNING