WARNING!
When drilling into any vehicle surface, make sure the area is free from any electrical wires, fuel lines, vehicle upholstery, etc. that could
be damaged.
WARNING!
This unit is a safety device and it must be connected to its own seperate fused power point to assure its continued operation should
any other electrical accessory fail.
PATTERN MODE FLASH PATTERNS SYNC.
SAE J595
CA T13
SAE J845
ECE R65
RED AMBER BLUE WHITE RED AMBER BLUE
RED AMBER BLUE WHITE
RED AMBER BLUE
(140
°
) (140
°
) (140
°
) (100
°
)
ED3777X Series Flash Pattern Chart:
1
1
Single Flash 75FPM
sim. Phase1
yes
Class
1
Class 1 Class
1
Class 1 Class
B
Class B Class
B Class 1 Class 1 Class 1 Class 1 N/C
N/C
N/C
2
Single Flash 75FPM
sim. Phase2
yes
Class
1
Class 1 Class
1
Class 1 Class
B
Class B Class
B Class 1 Class 1 Class 1 Class 1 N/C
N/C
N/C
3
Single Flash 75FPM
Alt.
yes
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
2
4
Single Flash 120FPM
sim. Phase1
yes
Class
1
Class 1 Class
1
Class 1 N/C
N/C
N/C Class 1 Class 1 Class 1 Class 1 Class
1
Class 1 Class
1
5
Single Flash 120FPM
sim. phase2
yes
Class
1
Class 1 Class
1
Class 1 N/C
N/C
N/C Class 1 Class 1 Class 1 Class 1 Class
1
Class 1 Class
1
6
Single Flash 120FPM
Alt.
yes
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
3
7
Double Flash 75FPM
sim. Phase1
yes
Class
1
Class 1 Class
1
Class 1 N/C
N/C
N/C Class 1 Class 1 Class 1 Class 1 N/C
N/C
N/C
8
Double Flash 75FPM
sim. phase2
yes
Class
1
Class 1 Class
1
Class 1 N/C
N/C
N/C Class 1 Class 1 Class 1 Class 1 N/C
N/C
N/C
9
Double Flash 75FPM
Alt.
yes
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
4
10 Double Flash
120FPM sim. Phase1 yes
Class
1
Class 1 Class
1
Class 1 N/C
N/C
N/C Class 1 Class 1 Class 1 Class 1 Class
1
Class 1 Class
1
11 Double Flash
120FPM sim. phase2 yes
Class
1
Class 1 Class
1
Class 1 N/C
N/C
N/C Class 1 Class 1 Class 1 Class 1 Class
1
Class 1 Class
1
12 Double Flash
120FPM Alt.
yes
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
5
13-De-
fault
Quad Flash 75FPM
sim. Phase1
yes
Class
1
Class 1 Class
1
Class 2 N/C
N/C
N/C Class 1 Class 1 Class 1 Class 2 N/C
N/C
N/C
14 Quad Flash 75FPM
sim. Phase2
yes
Class
1
Class 1 Class
1
Class 2 N/C
N/C
N/C Class 1 Class 1 Class 1 Class 2 N/C
N/C
N/C
15 Quad Flash 75FPM
Alt.
yes
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
6
16 Quad Flash 150FPM
sim. Phase1
yes
Class
1
Class 1 Class
1
Class 2 N/C
N/C
N/C Class 1 Class 2 Class 2 Class 2 N/C
N/C
N/C
17 Quad Flash 150FPM
sim. Phase2
yes
Class
1
Class 1 Class
1
Class 2 N/C
N/C
N/C Class 1 Class 2 Class 2 Class 2 N/C
N/C
N/C
18 Quad Flash 150FPM
Alt
yes
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
Page 3 of 9