Space heating 500ml metres
b)
Weight: Complete appliance = 550 kg; The Ecco Stove must be installed onto a structural hearth
capable of bearing this weight.
c)
Air Supply – UK 27.5 cm sq.: outside UK to those countries local requirements. Vents to be fitted
to outside and positioned such that they are not liable to block. Additional ventilation
requirement may be needed if the stove is operated simultaneously with other heating
appliances. It is important to ensure adequate supply of combustion and ventilation air.
d)
Extractor fans: No extractor fans are to be fitted in the same room as the Ecco Stove.
e)
Flue draught: Minimum cold flue draught to be .04 inches water gauge, maximum .06 inches
water gauge.
f)
Flue gas mass flow: 7.8gs
g)
Flue gas temperature: Average 247˚ C at nominal output.
h)
Flue outlet: 150mm top exit (Dampers may be necessary if the flue draught is in excess of 0.4”
water gauge). This pipe must include a soot door/access plate within 200 mm of the stoves top.
i)
Heat energy stored 120.7 MJ
j)
Co-concentration at 0.30@13%O
2.
Excessive flue draught may remove too much heat from the
Ecco Stove on slow combustion. A damper may be fitted into the flue pipe off the stove to
reduce draught but only closed after the firing process is completed – dampers must always
allow 20% of the flue area unclosed.
24.DUCTED WARM AIR ( WHEN AVAILABLE)
By fitting the hot box with one extra trim between it and the stoves top, up to
four 100mm diameter rigid pipes can be fitted off the stoves top to other rooms.
These pipes simply push into the openings in the top of the hot box.
Grilles with spigots are available separately along with rigid 100mm pipes and
100mm alloy flexible tubing (none of which are included as standard). Maximum
duct length per output is 1.5 metres. Each duct must rise constantly to its point
of emission into the adjacent room (or the same room the Ecco Stove stands in)
with a minimum angle of 45⁰ for natural convection.
The rigid pipes are used as decorative outlets rather than flexible tubing visible
directly off the top of the hot box. A steel locating plate which clamps onto the
flue pipe is available to hold the rigid duct pipes in position for appearances only.
ducts off