8
17.
How to customize the SMS message for INPUT – 1
You can customize the SMS message that the unit sends back when this input-1 is triggered to suit
different applications.
The default SMS messages send by the unit is:
When the input-1 is connected to ground:
The gate is closed.
When the input-1 is open circuit:
The gate is open.
You can program different messages by sending SMS message as follows:
9999RS
.
_ _ _
(Max 25 correctors)
_ _ _
.
_ _ _
(Max 25 correctors)
_ _ _
.
The following is an example for changing the messages to “The Alarm is ON” and “The Alarm is OFF”
9999RS.
The Alarm is ON
.
The Alarm is OFF
.
9999
Default password.
“RS”
Meaning Status input-1
The Alarm is ON.
Is the SMS reply message when the status input is connected to ground.
The Alarm is OFF. I
s the SMS reply message when the status input is not connected to ground.
18.
INPUT - 2 : ALERT
This input can be used to ALERT someone on his mobile phone each time input-2 is triggered.
This can be used as a DOOR BELL or ALERT the user each time the gate opens.
This can be done by connecting a push button as a door bell or a read-switch to trigger when the
gate opens and connect them to input-2 wire and ground. Each time this input is connected to the
ground (triggered), the unit will send SMS message as is set in the system.
The default message for this input is: “The gate was opened”.
You can program the phone number and different message by sending SMS message as follows:
9999AL
.
(Phone number )
.
_ _ _
(message send - Max 25 correctors)
_ _ _
.
Following is an example for programming the user’s phone number and the message “Someone at the gate”
9999AL.0418347235.
Someone at the gate
.
9999
Default password.
“AL”
Alert input
“0418347235”
The users phone
“Someone at the gate”
The SMS message when input-2 is triggered.